Figure 11 – Hired-Hand RS-300 Door User Manual

Page 15

Advertising
background image

Part No. 4801-5157 Rev 11-05

RS-300 Door

Page 15 of 30

Power
Supply

Any
Normally
Open
Operator
Switch

Somfy
Motor

Red

Black

White

Green/
GND

Red

Neutral

GND

Figure 11

Sequential Relay Wiring Diagram

1. Turn OFF electrical power.

2. Locate limit switches at end of motor.

3. Refer to Figure 10. The OPEN position

and CLOSE position of the door curtain
have to be set. This is where the curtain will
automatically stop.

4. Remove the protective cap from the motor

head. Depress fully both limit switch push
buttons (if not already pushed). They will
automatically lock in the down position

5. Turn ON the electrical power switch and

check that the drive pipe rotates correctly. If
not, put the electrical switch in the OFF
position, disconnect all power sources, and
reverse the black and red motor connection
wires at the terminal block.

6. OPEN

Limit. Bring motor rotation into

desired open position. Turn OFF power
switch when position is reached. Unlock the
OPEN limit switch push button by

depressing and releasing it. This sets the
OPEN limit.

7. CLOSE

Limit.

Repeat the above procedure

to set the CLOSE limit.

8. Allow the motor to run in both directions,

until it shuts off in the stop positions.

NOTE: Because of the built in thermal

protection feature, the motor may shut off
automatically after running without
interruption for an extended period of
time. Please wait until the motor has
cooled off and is ready for operation
again, (approximately 10-15 minutes).

9. Changing the Set Stop Position

Press the limit switch adjustment button that
lies in the direction of rotation. Bring the
curtain into the desired stop position.
Release the limit switch adjustment button
by pressing it down again.


7.4

Sequential Relay Wiring for Somfy Motor

A Sequential Relay can be used to operate an RS-300 Door’s push buttons or pull switches. This is required when
more that one switch is desired, for example, one on each side of the door. A kit (Switch for Tube Motor) is
available as RollSeal-Green part number 6450-6004. A wiring diagram is shown at the right in Figure 11.










Advertising