Appendix A: Specifications and Parameter

Settings 56

Hazard Classification

(See Appendix B, Area
Classifications / Protection

Concepts.)

Explosion Proof, prevent flame propagation

CSA/US
Class 1, Division 1, Groups C and D

Class 1, Division 2, Groups A through D

Temp code – T4A
Enclosure Type – 4X

CENELEC/ATEX approved Zone 1

Type : EExd IIB T4

Threads

Electrical service: ¾ inch NPT conduit
cooling base service: ¼ inch NPT

Mounting

M-3 mounting fixture –height adjustable pedestal with 360 ° swivel –

70 ° to +70 ° vertical

Torque Spec, Lid Bolts

50in-lbs,+/-5 ; 5.5N-m

Air

View port purge 20psig min., 1 SCFM

Cooling (For ambient

environments over 120F)

WATER: 10 gph (37.8 lph)
AIR: Vortex, V208-15H, 10SCFM minimum

Reference manufacturer data for pressure specs.

Weight/Dimensions

48 Pounds (22 Kg) / 5 x 12.5 x 8.5 in (127 x 318 x 217 mm)

Varying Flame

Luminescence

The LumaSense E

2

T QUASAR M8100-EXP automatically compensates

for low and varying target emissivity (luminescence) and minimizes

the effects of attenuation by intervening media, such as rain, snow
and fog.

Advertising