32

:AUToset

Perform an automatic setup in order to optimize the acquisition parameters.

Syntax

:AUToset

:CHANnel<X>:BWLimit

Enable or disable the bandwidth limit function.

Syntax

:CHANnel<X>:BWLimit {0|1}

:CHANnel<X>:BWLimit?

Arguments

<X>→Specify the channel number (1|2|3|4)

0→Disable bandwidth limit

1→Enable bandwidth limit

Returns

<NR1>

:CHANnel<X>:COUPling

Select the different coupling states for the oscilloscope.

Syntax

:CHANnel<X>:COUPling {0|1|2}

:CHANnel<X>:COUPling?

Arguments

<X>→Specify the channel number (1|2|3|4)

0→Place scope in AC coupling state 1→Place scope in DC coupling state

2→Place scope in grounding state

Returns

<NR1>