6 analog output (optional) – KANOMAX 2211 Handheld IAQ Monitor User Manual

Page 35

Advertising
background image

30

Display

Procedure


<To download measurement condition>
Press
M**** ” (※Must type in 4 digits)
Type in the desired page number after “AM”.

Contents

Measuring Mode

000: CALCULATION Mode
001: %OA Mode

Sampling Time

Number of Data

Calculation setting

CALCULATION -- AVG: average, INS: Instant
%OA -- TMP: temperature CO2; CO

2

Atmosphere pressure

Display

Procedure

<To download measurement conditions of all pages>
Press

[B ]

, after[AB]

The data will be displayed.

Display

Procedure

<Error Message>
"ED" will be returned if the number of pages etc. is incorrect-inputted.


6.6 Analog Output (Optional)

Data Update Interval ………1 second

Load Impedance…… Above 5KΩ

Output Current………………DC 0-1V


For the analog output, you must select one setting from the table below.

Output Range

Conversion Formula

(Voltage: )

0 – 50 ppm

C = 50 x V ppm

0 – 100 ppm

C = 100 x ppm

0 – 250 ppm

C = 250 x ppm

CO C

0 – 500 ppm

C = 500 x ppm

0 – 500 ppm

M = 500 x ppm

0 – 1000 ppm

M = 1000 x ppm

0 – 2500 ppm

M = 2500 x ppm

CO

2

M

0 – 5000 ppm

M = 5000 x ppm

0 – 50

T = 50 x

0 –100

T = 100 x

-20 – 30

T = 50 x – 20

Temperatur
e
T

-20 – 80

T = 100 x – 20

32 – 122

o

F

F = 90 x + 32

o

F

32 – 212

o

F

F = 180 x + 32

o

F

-4 – 86

o

F

F = 90 x – 4

o

F

Temperatur
e
(F)

-4 – 176

o

F

F = 180 x – 4

o

F

0 – 50 %RH

H = 50 x %RH

Humidity
(H)

0 – 100 %RH

H = 100 x %RH

Analog Output Port

AM
CTH;000;001;003;AVG;1013

① ②

AB
CTH;000;001;003;AVG;1013
CTH;001;001;005;TMP;1013

ED