8 .2 .3 basic ethernet settings – KROHNE Summit 8800 Vol 3 User Manual
Page 122

122
www.krohne.com
08/2013 - MA SUMMIT 8800 Vol3 R02 en
SUMMIT 8800
COMMUNICATION
08
8 .2 .2 Basic RS 232/485 serial port settings
When selecting the serial ports, the user is presented from the drop down a list of options for
various types of communication:
Figure 167 Serial port type selection and a typical setting
For RS232/485 links the following settings are always required:
Baud rate
The speed of transmission in bits per second between 300 and 38400.
Parity
A check on correct transmission: none, odd, even, space or mark.
Stop bits
Gap between two transmitted words, 1 or 2 stop bits
Mode
RS232 or RS 485
Word size
Size of 1 word: 7 or 8 bits
It is essential to match these settings with the settings of the devices communicating with, oth-
erwise garbled information will be transferred.
8 .2 .3 Basic Ethernet settings
To establish communication to the SUMMIT 8800 over Ethernet, the basic settings under the
general section is always needed: