06
6 .9 .3 3D graph profile
Up to 12 profiles can be defined for one graph, each defining a curve for the graph.
For example, profile 1 can be a curve of flow rate (X) against error (Y). Profiles 2 and 3 could be
the same curve at different pressures.
These curves can be presented in an X-Y graph or X-Y-Z graph depending on the min and max
values in Figure 88: if min and max are the same an X-Y graph will be shown, otherwise an X-Y-
Z graph will be shown.
Each profile can be:
Created
Press new
Changed
Select the profile and press edit
Removed
Select the profile and press delete
Figure 91 New graph profile
Then the next window will appear with on top::
Figure 92 Graph profile, Top
With as settings:
Colour
The colour of the graph associated with this profile
Data format
Select if the curve should be based on values to be entered or on variables in the ID list