4 .3 manually change date and time – KROHNE Summit 8800 Vol 3 User Manual
Page 25

25
www.krohne.com
08/2013 - MA SUMMIT 8800 Vol3 R02 en
SUMMIT 8800
DATE & TIME
04
Figure 8 SNTP Date & time unicast settings
Server timeout
The timeout that applies to each server, after which the next available server in
the list is tried. It is recommended that this value is a factor of the maximum
time without adjustment.
Poll interval
Frequency of the flow computer polling the time server. It is recommended that
this value is not divisible by 60.
Number of servers
The number of time servers the flow computer can connect to.
Time server
IP address of each server.
Figure 9 SNTP Date & time broadcast settings
Broadcast timeout
The flow computer the waits for a broadcast before giving an alarm. It is
recommended that this value is a factor of the maximum time without
adjustment.
Broadcast domain.
IP address on the client subnet for the client operating in broadcast mode to
listen for time updates from broadcast servers.
4 .3 Manually change date and time
To be able to set the date and time manually, a display item has to be created under “Security”
with the time in it. (see also next chapter).