8 .7 instromet ultrasonic protocol – KROHNE Summit 8800 Vol 3 User Manual
Page 147

147
www.krohne.com
08/2013 - MA SUMMIT 8800 Vol3 R02 en
SUMMIT 8800
COMMUNICATION
08
761-767
Hourly records
03
781-787
Batch/ Daily records
03
1001-1999
Boolean values
01
05 and 15!
2001-6000
Not assigned
6001-7000
Log history indexes
03
06
6301
Log event index
03
06
7001-7599
32 bit floating point
03
06
7601-7999
events
03
06
8001-9000
quality &
configuration
03
06 16?
9999-10000
Time synchronisation 03
06
Details to be defined.
8 .7 Instromet Ultrasonic protocol
The Elster/Instromet Q-sonic ultrasonic gas meter can be set to two protocols:
Instromet protocol
The original protocol specifically designed by Instromet for the
Q-sonic
Modbus protocol
The most common protocol, developed later
The SUMMIT 8800 supports both protocols.
To use the Instromet protocol, go to hardware, select a serial port and choose Instromet ultra-
sonic:
Figure 198 Figure 198 Instromet protocol serial settings