Technical data – KROHNE OPTIFLEX 2200 C_F EN User Manual
Page 123

TECHNICAL DATA
8
123
OPTIFLEX 2200 C/F
www.krohne.com
07/2013 - 4000668002 - HB OPTIFLEX 2200 R02 en
8.4 Pressure / flange temperature graph for probe selection
Make sure that the transmitters are used within their operating limits. Obey the temperature
limits of the process seal and the flange.
Figure 8-4: Pressure/temperature graph for probe selection in °C and barg
Figure 8-5: Pressure/temperature graph for probe selection in °F and psig
1 Process pressure, P
s
[barg]
2 Process connection temperature, T [°C]
3 Process pressure, P
s
[psig]
4 Process connection temperature, T [°F]
5 All probes
6 High-Temperature (HT) version of the Ø2 mm / 0.08¨ single cable probe
WARNING!
The minimum and maximum process connection temperature and the minimum and maximum
process pressure also depends on the gasket material selected. Refer to "Pressure and
temperature ranges" on page 18
.