Installation, 9 how to turn or remove the signal converter – KROHNE OPTIFLEX 2200 C_F EN User Manual
Page 43

INSTALLATION
3
43
OPTIFLEX 2200 C/F
www.krohne.com
07/2013 - 4000668002 - HB OPTIFLEX 2200 R02 en
3 Make sure the wall support is correctly attached to the wall.
3.8.9 How to turn or remove the signal converter
The converter turns 360°. The converter can be removed from the process connection assembly
under process conditions.
Figure 3-39: How to turn or remove the signal converter
1 Tool: 5 mm Allen wrench (not supplied) for the lock screw on the signal converter
2 Cover for the coaxial hole on top of the process connection assembly
CAUTION!
Do not loosen the 4 socket head screws on the process connection assembly.
If you remove the housing, put a cover on the the coaxial hole on top of the process connection
assembly.
When the housing is attached to the process connection assembly, tighten the lock screw with
the 5 mm Allen wrench 1.