• Use a 2.5 mm Allen wrench to attach and tighten a HC M5×5 screw (lock screw) to the bottom
segment of tube.
3.8.4 How to install a device with a flange connection
Equipment needed:
• Device
• Gasket (not supplied)
• Wrench (not supplied)
• Make sure the flange on the nozzle is level.
• Make sure that you use the applicable gasket for the flange and the process.
• Align the gasket correctly on the flange facing of the nozzle.
• Lower the probe carefully into the tank.
i
For more data on cable probes, refer to
How to install a cable probe in the tank
on page 41.
• Tighten the flange bolts.
i
Refer to local rules and regulations for the correct torque to apply to the bolts.
Figure 3-32: How to assemble the segmented coaxial probe: part 3
CAUTION!
If the lock screw is not tight, the device will not measure correctly.
Figure 3-33: Flange connection