6operation – SHIMPO CEG-2000 User Manual
Page 10

-7-
6
Operation
6.1
Overview
• What to do when the detector has been connected and adjusted and the settings have
already been entered.
• What to do when the measurement head has been replaced
In this section, we will explain the procedures for the above two situations.
6.1.1
What to do when the detector has been connected and adjusted and
the settings have already been entered.
Please use the following procedure.
(1) Power on
Turn on the power switch in the rear of the unit (press the side marked with a circle)
to supply power (85-265V AC and 50/60Hz). The unit will start up in Measurement
Mode.
In Measurement Mode, hold down the right arrow (MAS) key for two seconds.
Holding the key down for an additional two seconds switches to Clear Master Match.
(2) Clearing the master matching data
Clear the master matching data as necessary. For details, refer to 6.4.3 “Clearing the
Master Match.”
(3) Master matching
Now match to a master. For details, refer to 6.4.1 “Master matching.”
(4) Measuring
In Measurement Mode, press the ENT key once, the unit will be set to Hold
Measurement Value. This can be cleared by pressing the RST key. However, if the
master match was unsuccessful, the measured value cannot be saved. For details,
please refer to 6.2 “Measuring.”