Force rf, Force rf 11 – Badger Meter GALAXY User Manual

Page 11

Advertising
background image

Force RF

The Force RF command is used to force an endpoint transmission, most commonly to test installation success An initial read

must be performed prior to forcing a transmission

1 To force an endpoint transmission, align the optical

read head of the IR cable with the IR port of the TR3

endpoint and tap the Force RF button




Result: A warning screen is displayed as shown in

Figure 13.

Figure 12: Force RF

2 Tap Yes to continue

Result: Once a transmission has been sent, the display

returns to the TR3 Programmer screen.

NOTE:

N

Tap No if you want to cancel the

Force RF command

Figure 13: Force RF Warning screen

3 If the Force RF command is unsuccessful, one of two

transmission failed screens is displayed, depending

on whether there is a partial response or no

response from the endpoint
If either screen is displayed, tap OK to close the

transmission failed screen and repeat steps 1 and

2 until you get a successful transmission Refer to

“IR Reading Error” on

page 22

for additional help

NOTE:

N

Allow at least 30 seconds between Force RF

commands

Figure 14: Transmission failed

Programming Manual

Page 11

February 2013

Advertising