Read register, Read register 12 – Badger Meter GALAXY User Manual

Page 12

Advertising
background image

Read Register

The Read Reg button is used to read the register on an encoder, most commonly to verify a tamper repair

NOTE:

N

The Read Reg button does not display for an RTR

1 Align the optical read head of the IR cable with the IR

port of the endpoint and tap the Read Reg button



Result: A screen is displayed warning that reading the

register will change the hourly interval data. See

Figure 16.

Figure 15: Read Register

2 Tap Yes to continue

NOTE:

N

Tap No if you want to cancel the

read register command

Result: The current reading from the encoder register is

displayed in the Reading field.

Figure 16: Read Register Warning screen

If Read Reg is used to verify a tamper repair, the

reading displays in the Reading field instead of the

word "TAMPER."

If the TAMPER message does not clear, recheck the wire

splice and repeat steps 1 and 2.

IMPORTANT

You must wait 90 seconds between Read Reg

commands to allow endpoint diagnostics to complete.

Figure 17: Read Register completed

GALAXY® Programmer – Handheld Programming Software for TR3 and TR2 Endpoints

Page 12

February 2013

Advertising