Clearing a tamper, Ade tamper repair, Rtr tamper repair – Badger Meter GALAXY User Manual

Page 13: Clearing a tamper 13, Oder tamper repair 13 rtr tamper repair 13

Advertising
background image

Clearing a Tamper

When a tamper occurs, the word "TAMPER" displays in the Reading field, and "DISCONNECTED" displays in red at the bottom

of the screen Follow the steps below to repair and clear a tamper

Figure 18: Tamper

Encoder Tamper Repair

1 To clear a tamper on an ADE or ELCD endpoint, repair the wire connection from the endpoint to the encoder
2 Check to see if the repair was successful by using the Read Reg button to read the encoder register Refer to

“Read Register” on

page 12

if you need help

When the repair is verified, the process is complete The encoder endpoint is automatically updated to reflect the register

value in the first hour after the wires are repaired

RTR Tamper Repair

1 To clear a tamper on an RTR endpoint, repair the wire connection from the endpoint to the register
2 When the wires are successfully reconnected, program the endpoint Refer to

“Programming a TR3 Endpoint - RTR only” on

page 14

Programming Manual

Page 13

February 2013

Advertising