INSTALLING THE HR-E LCD ENCODER

Bayonet Mount

The fully potted encoder assembly has a bayonet mount compatible with all Recordall Disc, Turbo Series, Compound Series,

Combo Series and Fire Series meters and assemblies The bayonet mount positions the encoder in any of four orientations for

visual reading convenience The HR-E LCD Encoder can be removed from the meter without disrupting water service
The HR-E LCD Encoder is available factory pre-wired to Badger Meter AMR/AMI products The HR-E LCD Encoder is

permanently sealed to eliminate the intrusion of moisture, dirt, or other contaminants, and is suitable for installation in all

environments, including meter pits subject to continuous submergence
Install the encoder on the water meter and secure it using the tamper-proof screw provided

Wire Connections

The HR-E LCD is provided as either a factory-wired assembly or as an encoder with pre-sized wire harness available for

connection in the field Standardized lead lengths are 3, 10, 25, and 75 feet See ADE-I-01 for instructions

308 In-Line Connector

The Badger Meter 308 In-line connector is an optional feature that allows connectivity to a AMR/AMI devices without the

need for a field splice kit See ORI-I-69 for instructions