Installation and Programming Manual

INTRODUCTION

Product Unpacking and Inspection

Upon opening the shipping container, visually inspect the product and applicable accessories for any physical damage such

as scratches, loose or broken parts, or any other sign of damage that may have occurred during shipment

NOTE:

N

If damage is found, request an inspection by the carrier’s agent within 48 hours of delivery and file a claim with the

carrier A claim for equipment damage in transit is the sole responsibility of the purchaser

License Requirements

This device complies with Part 15 of the FCC Rules Operation of this device is subject to the following two conditions: (1) This

device may not cause harmful interference, and (2) this device must accept any interference received, including interference

that may cause undesired operation Any changes made by the user not approved by Badger Meter can void the user’s

authority to operate the equipment

Audience and Purpose

This manual is intended to be used by utilities for installing and programming the HR-E LCD Encoder

PRODUCT OVERVIEW

Description

The HR-E LCD Encoder is a fully electronic, solid-state encoder with no moving parts

Compatibility

The HR-E LCD Encoder is designed for use with all current Badger Meter Recordall

®

Disc, Turbo Series, Compound Series,

Combo Series and Fire Service meters and assemblies The HR-E LCD Encoder provides connectivity with Badger Meter ORION

®

and GALAXY

®

AMR/AMI endpoints and other AMR/AMI technology solutions approved by Badger Meter

LCD Display

The HR-E LCD Encoder has a nine-digit Liquid Crystal Display (LCD) to show consumption, flow and alarm information
There is no need to activate the display The display automatically toggles between 9-digit and 6-digit consumption

(segmented leak detector in this mode), rate of flow and meter model

Extended Visual

Reading Resolution

Typical Billing

Segments

Status

Indicators

IR Programming

Port

1212

4-Digit

Date Code

E LCD

HR

Multiplier Value

(x10, x100, x1000, x10,000)

In 6-digit mode, the

last digit is a dashed

line that becomes a

flow finder

Figure 1: HR-E LCD Encoder Face

Page 5

December 2012