Installation and Programming Manual

Status Indicators

Status indicators are sent as part of the encoder message to AMR/AMI systems that are capable of receiving an extended

message, such as ORION ME and SE endpoints The details can also be read through an IR interface
Status indicators appear in the display as symbols that illuminate when the condition is active and dim when the condition

is eliminated
All HR-E LCD Encoders are delivered in a storage mode so that a meter alarm is not triggered During storage mode, the meter

model displays on the encoder As water begins to flow through the meter, the encoder switches from storage mode to

normal operation
The following chart indicates the HR-E LCD Encoder conditions when connected to a Badger Meter ORION ME/SE endpoint
The chart does not apply to ORION CE or GALAXY endpoints The HR-E LCD displays the indicators and sends information, but

the ORION CE and GALAXY endpoints ignore the extra information and do not report it

Status Indicator Icon

Status Description

HR-E LCD Display

HR-E LCD with ORION ME/

SE *Version 1.8 or higher

firmware required

Meter

functioning

correctly

Encoder operating correctly

Continuous display on

encoder as long as no other

status indicators are triggered

Indicator Status not sent to

the endpoint

Encoder alarm

Several potential conditions

may exist, including:

• Encoder removal

• Temperature limit

exceeded (34…140° F)

• Magnetic tamper

Encoder alarm remains

active for 35 days The alarm

automatically clears after 35

days if any of the 3 conditions

has not recurred

Encoder alarm sent to ORION

ME/SE endpoint

Reverse flow

Encoder detects reverse flow

Reverse flow alarm remains

active for 35 days The alarm

automatically clears after 35

days if reverse flow condition

has not recurred

Encoder detects reverse flow

and sends alarm message to

ORION ME/SE endpoint

Suspected leak

Encoder detects 24 hours

without one 15-minute

interval of no flow

The alarm clears automatically

when a 15-minute no-flow

interval occurs

Encoder detects suspected

leak and sends alarm message

to ORION ME/SE endpoint
If condition clears before

message is sent to the

endpoint, it is not reported

30 day no usage

No measured flow in past 30

days

The alarm is automatically

cleared once flow occurs

Encoder detects 30 days no

usage and sends alarm to

ORION ME/SE endpoint

End of life

battery indicator

Indicated battery life based on

pre-calculated consumption

Alarm activated at 19 years

and does not clear

Encoder sends alarm to ORION

ME/SE endpoint