Troubleshooting, Troubleshooting 23 – Badger Meter High Resolution LCD Encoders (HR-E LCD) User Manual

Page 23

Advertising
background image

Installation and Programming Manual

TROUBLESHOOTING

Issue

Probable Cause

Solution

Programmer screen is blank after a

Read

Bad connection

Check for damaged or broken wires

COM Port not specified

Select a COM Port from the IR Port

drop-down menu

Error message displayed after clicking

an option on the programmer screen

IR head not aligned with encoder

Align the IR head with the IR port on

the encoder

UPDATING THE FIRMWARE VERSION OF ADE TYPE ME/SE ENDPOINTS

For the HR-E LCD, ME/SE endpoints need to be high resolution version endpoints
This procedure should be used only for updating the firmware version of in-stock stand-alone encoder type “ADE” ME/

SE endpoints
Firmware version 1 9 or higher is required in these endpoints to use the HR-E LCD encoder The Attach Endpoints feature

updates the firmware version of the endpoint
To update the firmware version of an ADE type ME/SE endpoint:

1 Align and hold the IR head over the antenna at the bottom of the endpoint
2 Click the Attach Endpoint button

If the endpoint is properly aligned to the IR head, the programmer queries the endpoint, then updates its firmware version

If the programmer cannot find the endpoint, it displays this message:
In this case, reposition the IR head so it contacts the antenna on the

endpoint, then click OK

Page 23