Installation and Programming Manual

Read Errors

If no COM port is selected, this error message displays In this case, click OK, select the correct COM port, and try the

Read again

If the wrong COM port is selected, this error message displays In this case, click Cancel, select the correct COM port, and try

the Read again

Change Current Settings

If you need to change the settings for the current encoder, follow this procedure
To set a default value for any of the data fields:

1 Click the down arrow to the right of the field to display a drop-down list of values
2 Click on the value you want to set as the default for that field

NOTE:

N

You must set the default value for the Meter Type field before you set the Meter Model / Size field

The Rate of Flow Units do not have to be the same as the Unit of Measure (even in a cubic foot meter, the

flow rate can be gallons per minute)

Apply Current Settings

When you click Apply Current Settings, the displayed settings are programmed into the encoder and the encoder goes into

storage mode In storage mode, the encoder displays the meter type and unit of measure In this example, a Model 25 Disc

Meter measured in gallons:

GAL

The software retains the current settings until you perform another Read
If you have multiple encoders to program with the same parameters, just attach the IR head bracket to them, one at a time,

and click Apply Current Settings