Operation, Operating the meter, Normal operation (run) mode – Badger Meter MR Transmitter User Manual

Page 12: Programming operation (program) mode

Advertising
background image

OPERATION

Operating the Meter

The monitor has two modes of operation, referred to as RUN mode and PROGRAM mode as indicated on the display screen

readout . Normal operation will be in the run mode . To access the program mode, press MENU until the first programming

screen DISPLAY appears .

OTEE:

N

PROGRAM appears on left side of display .

After programming the meter, a password may be entered to prevent unauthorized access to programming .

Normal Operation (RUN) Mode

During normal operation, the transmitter will show RUN on the left side of the display . In RUN mode the flow rate and total

flow will alternate being shown as the default . The meter can also be set to show only flow rate or only flow total .

MENU

ENTER

Programming

Buttons

Figure 7: Programming buttons

The four buttons have the following function in RUN modeE:

MENU

Selects programming mode .

No function .

No function .

ENTER

The current total can be manually stored in the monitor's flash memory . Press and hold ENTER for 2

seconds . The display will respond with a flashing TOTALSVD and then will return to RUN mode .

RESET TOTAL

To reset the monitor's total display, press MENU and ENTER simultaneously until TOTALRST starts to

flash . The TOTALRST will stop flashing and the display will return to RUN mode at the conclusion of the

rest procedure .

Programming Operation (PROGRAM) Mode

The programming mode lets you change the configuration and adjust the calibration of the meter . The MR flow transmitter

has two types of configuration changes accessible in program mode:
1 . To view or change selections from a pre-defined list .
2 . To view or change numeric entries .
During programming operation, the following four button functions are provided:

MR Flow Transmitter

Page 12

November 2013

Advertising
This manual is related to the following products: