Introduction, Safety information, Unpacking and inspection – Badger Meter MR Transmitter User Manual

Page 5

Advertising
background image

INTRODUCTION

The MR flow transmitter is a state-of-the-art, microprocessor based variable area flow meter . It combines the rugged proven

technology of a piston-type, variable area flow meter with solid state circuitry including:
• Non-contact sensor electronics
• Electronic signal conditioning circuit
• Digital flow rate and total indication
• Proportional analog output
The product is sealed against industrial contamination by a NEMA 12 and 13 (IP 52/54) rated enclosure and is available for

either liquid or gas service .
The MR flow transmitter is capable of calculating and displaying both flow rate and total accumulated flow . The flow rate and

total flow can be displayed in any of the user selectable measurement units . The monitor’s large 8 digit numeric liquid crystal

display makes extended range viewing practical . The second 8 character alphanumeric display provides for selectable units

viewing in RUN mode and prompts for variables in PROGRAM mode .
All MR flow transmitters come pre-calibrated from the factory . However, the unit may be adjusted by the user to meet

specific system requirements . Calibration parameters are included for:
• Specific gravity compensation (all fluids)
• Viscosity compensation (petroleum-based fluids)
• Pressure and temperature compensation (pneumatic applications)
All meters include an analog output that can be configured for 0…5V DC, 0…10V DC, or 4…20 mA current loop . Applications

for the MR flow transmitter include:
• Bearing lubrication
• Case drain verification
• Gun drill and machine cooling
• Pump flow outputs

SAFETY INFORMATION

The installation of this flow meter must comply with all applicable federal, state, and local rules, regulations, and codes .
Failure to read and follow these instructions can lead to misapplication or misuse of this product, resulting in personal injury

and damage to equipment .

UNPACKING AND INSPECTION

Upon opening the shipping container, visually inspect the product and applicable accessories for any physical damage such

as scratches, loose or broken parts, or any other sign of damage that may have occurred during shipment .

OTEE:

N

If damage is found, request an inspection by the carrier's agent within 48 hours of delivery and file a claim with the

carries . A claim for equipment damage in transit is the sole responsibility of the purchaser .

User Manual

Page 5

November 2013

Advertising
This manual is related to the following products: