Badger Meter MR Transmitter User Manual

Page 22

Advertising
background image

LIQUIDS

Fluid

Specific

Gravity

Correction

Factor

A

luminum

Br

ass

T16 SST

T303 SST

Vit

on®

EPR

Poly

car

bona

te

N

ylon

Pyr

ex®

Air

1 .0

1 .000

R

R

R

R

R

R

R

R

R

Argon (A)

1 .38

1 .175

R

R

R

R

R

R

R

R

R

Carbon Dioxide (CO

2

)

1 .53

1 .237

R

R

R

R

R

R

R

R

R

Freon 11 (CCI

3

F)

4 .92

2 .218

R

R

R

R

R

R

R

R

R

Freon 12 (CCI

2

F)

4 .26

2 .060

R

R

R

R

R

R

R

R

R

Helium (HE)

0 .14

0 .374

R

R

R

R

R

R

R

R

R

Hydrogen (H

2

)

0 .07

0 .265

R

R

R

R

R

R

R

R

R

Natural Gas

0 .60

0 .775

C

C

R

C

R

N

C

R

R

Nitrogen (N

2

)

0 .97

0 .985

C

C

R

R

R

R

C

R

R

Oxygen (O

2

)

1 .10

1 .049

R

R

R

R

R

R

R

R

R

Propane C

3

H

8

)

1 .57

1 .253

R

R

R

R

R

N

N

R

R

R–Recommended
N–Not Recommended
C–Consult Factory

Table 4: Gaseous fluid selection chart

4

2

1

3

Flow Transmitter

FLOW

Model H600A-000-MR

S.N.: 78500

Date: 0412

Flow Transmitter

3500 PSI/241 BARS MAX

OIL

RUN

C

K

A

D

B

F E

G

J

H

I

Figure 11: Dimensions

MR Flow Transmitter

Page 22

November 2013

Advertising