APPLICATION INFORMATION, LIQUID

Viscosity Effect (SUS/cSt)

The design uses a precision machined, sharp- edged orifice and biasing calibration spring that assures operating stability and

accuracy over the wide viscosity range common to many fluids . Generally, high flow models of each meter size provide good

accuracy over a viscosity range of 40…500 SUS (4 .2…109 cSt) .

Density Effect (specific gravity)

Any fluid density change from stated standards has a proportional effect on meter accuracy . Corrections for more or less

dense fluids can be made to standard scales using the following correction factor:

1 0

.

Specific Gravity

For water/water-based meters

0 876

.

Specific Gravity

For petroleum-based meters

Application Information Pneumatic

OTEE:

N

Pressure and temperature readings must be taken at the flow meter inlet to ensure accurate correction factors .

The pneumatic flow meter is calibrated for air in standard cubic feet per minute (scfm) at 1 .0 s .g . (70° F @ 100 psi), and liter per

second (lps) at 1 .0 s .g . (21° C @ 6 .9 bar) .

Pressure

Gauge

Air Bleed Off

To Equipment

Pressure

Source

Adjustable

Valve

Flow

Meter

Temp

Figure 10: System schematic

DETERMINE FLOW RATES USING DIFFERENT PRESSURES & TEMPERATURES

scfm actual

scfm indicated

f x f x f

(

)

(

)

=

1

3

2

Where

f

1

= Conversion Factor for Inlet Pressure

f

2

= Conversion Factor for Inlet Pressure

f

3

= Conversion Factor for Inlet Pressure

Table 1–Temperature Correction Factor (f

1

) Operating Pressure

psig

25

50

75

100

125

150

175

200

225

250

BAR

1 .7

3 .5

5 .2

6 .9

8 .6

10 .4

12 .1

13 .8

15 .5

17 .2

kPa

172

345

517

689

862

1034

1207

1379

1551

1724

f

1

1 .700

1 .331

1 .131

1 .00

0 .902

0 .835

0 .778

0 .731

0 .692

0 .658

f

kPa

1

790 857

101 357

=

+

.

.

f

BAR

1

7 914

1 014

=

+

.

.

f

psig

1

114 7

14 7

=

+

.

.

Table 2–Temperature Correction Factor (f

2

)

°F

10

30

50

70

90

110

130

150

170

190

°C

–12 .2

–1 .1

9 .9

21 .0

32 .1

43

54

65

76

88

f

2

0 .942

0 .962

0 .981

1 .00

1 .018

1 .037

1 .055

1 .072

1 .090

1 .107