4.3.1

Manual Adjust (manual speed adjust)

Used to manually control speed of pump. Use up and down arrows to adjust
the speed while the pump is running or set % (percent) Motor Speed in this
menu.

Press SELECT RUN MODE button until Manual Speed Adjust is displayed in
the top line of the display.

To configure the pump output speed, navigate to Manual Speed Adjust menu
by using short-cut method described above, or by pressing MENU button, then
selecting Input Setup, Input Modes, and then Manual Adjust.

Press UP or DOWN arrow to scroll through 0 - 9 on selected digit.

Press RIGHT arrow to scroll over to next digit to right. If you pass your desired
digit, you can easily scroll back by continuously pressing RIGHT button.

Press ENTER to save changes.

If you used short-cut to enter Manual Speed Adjust setup, then just press and
hold Select Run Mode button until Run Mode screen is displayed.

If you used Menu button to navigate to Manual Speed Adjust setup, you must
navigate back out of menu structure. To do this you must select <-Esc at
bottom of every screen menu until you see Run Mode screen displayed.

Tip! This feature can be combined with Contact Input feature to allow for
remote Start and Stop of pump. Can be used with PLC, foot pedal, push
button, or other external controls.

Manual Speed Adjust

OFF

Manual Speed Adjust

Press START to run

Tip!

Run Mode

(operating Input Mode)

- Speed Adjust
Input Pump Speed:

Set % motor speed.
Press ENTER to set.

00.0%

0

SELECT RUN MODE button also serves as a shortcut button.
Press and Hold SELECT RUN MODE button to enter program
menu for currently displayed Run Mode.
Once you have programed your Run Mode, Press ENTER to save
changes.
Press and Hold SELECT RUN MODE button to jump back to
current Run Mode of the pump.
Then Press START button to start pump with new settings applied.

In Manual Speed Adjust mode, you can view
pump output by pressing RIGHT arrow (see
screen shot). RIGHT arrow is a convenient
way to scroll through multiple read-only
screens during normal operating mode of
pump.

Tip!

Manual Speed Adjust

GAL/DAY

228

Е

Й

ДИ

Displays current rotor direction

Flex-Pro

4.3

Input Setup (operating mode configuration)