5 wiring terminals and i/o schematics, Flex-pro, Warning – Blue-White FLEX-PRO A4 ProSeries Peristaltic Pump User Manual

Page 9: Output input, T2 t4, T6 power, T8 t9

Advertising
background image

Page 9

Risk of electric shock – cord connected models are supplied with a grounding
conductor and grounding-type attachment plug. To reduce risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.

Electrical connections and grounding (earthing) must conform to local wiring codes.
Be certain that a grounding conductor is connected to terminal T11-1 located in the
wiring compartment.

Risk of electric shock - Disconnect electricity before removing the wiring
compartment cover.

2.5

Wiring Terminals and I/O Schematics

Flex-Pro

OUTPUT

INPUT

3

1
2

T3

DRY

RMT

COM

1
2
3

T1

PULSE

GND (-)

4-20 (+)

0-10 (+)

+15 VDC

1
2

T2

T4

3

1 2

(+)

FVS

SIG

(-)

2

1

FREQ.

(-)

(+)

T5

1 2

4-20

mA

T6

POWER

FUSE 5A SLOW BLOW
(20 X 5MM)

F1

2

3

1

GROUND

N EUTRAL
(COMMON)

LINE
(HOT)

T11

N.C.

COM

N.O.

N.O.

COM

N.C.

CC3

CC2

T8

T9

3

1
2

3

1
2

3

1
2

CC1

N.O.

COM

N.C.

T10

1 2 3

N.C. COM. N.O.

RELAY

OUT

T7

(-)

(+)

INPUT:
4-20 mA

INPUT:
0-10V DC

INPUT:
FREQUENCY, AC
SINE WAVE, TTL,
CMOS

FUNCTION

TERMINAL PIN #

RATING

ELECTRICAL SP.

BLOCK DIAGRAM

T1

T1

T1

T1

T2

T1

INPUT:
FVS SYSTEM
(FLOW VERIFICATION
SENSOR)
FV SENSOR ONLY

T4

T4

T4

(+) POSITIVE

3

2

1

2

1

2

1

2

3

(-) NEGATIVE

(+) POSITIVE

(-) NEGATIVE

(+) POSITIVE

(-) NEGATIVE

(+) POSITIVE

SIGNAL

(-) NEGATIVE

INPUT:
REMOTE
START / STOP
(DRY CONTACT C.)
INPUT:
REMOTE
START / STOP
(WET CONTACT C.)

OUTPUT:
4-20 mA

OUTPUT:
FREQUENCY -
OPEN COLLECTOR

OUTPUT:
RELAY, 6 AMP

OUTPUT:
CONTACT
CLOSURE 1

INPUT:
POWER

OUTPUT:
CONTACT
CLOSURE 2

OUTPUT:
CONTACT
CLOSURE 3

FUSE

T3

T3

1

2

T3

T3

2

3

T6

T6

2

1

T5

T5

2

1

(+) POSITIVE

(-) NEGATIVE

(+) POSITIVE

(-) NEGATIVE

T7

1

T7

T7

2

3

NORM. CLOSED

COMMON

NORM. OPEN

T8

1

T8

T8

2

3

NORM. OPEN

COMMON

NORM. CLOSED

T9

1

T9

T9

2

3

NORM. OPEN

COMMON

NORM. CLOSED

T10

1

T10

T10

2

3

NORM. OPEN

COMMON

NORM. CLOSED

T11

1

T11

T11

2

3

GROUND

NEUTRAL

LINE (HOT)

F1

NA

5 AMP

120 OHM
IMPEDANCE, NON
POWERED LOOP

6 TO 30 VOLT DC
1 AMP MAX.

120 OHM
RESISTANCE
ACTIVE LOOP

OPEN COLLECTOR
0-1000 Hz
50% DUTY CYCLE

Form C
6 AMP MAX AT
250 VAC,
5 AMP MAX AT
30 VOLT DC

Form C
1 AMP MAX AT
125 VOLT AC,
0.8 AMP MAX AT
30 VOLT DC

Form C
1 AMP MAX AT
125 VOLT AC,
0.8 AMP MAX AT
30 VOLT DC

Form C
1 AMP MAX AT
125 VOLT AC,
0.8 AMP MAX AT
30 VOLT DC

5A SLOW BLOW
(20 X 5MM)

1
2
3

T1

PULSE

GND (-)

4-20 (+)

1
2
3

T1

PULSE

GND (-)

4-20 (+)

0-10 (+)

+15 VDC

1
2

T2

0-1000 HZ MAX.

(-) NEGATIVE

(+) POSITIVE

(+) POSITIVE

(-) NEGATIVE

NO VOLTAGE

96 TO 264 VOLT AC,
50 / 60 HZ
A3 = 220W
A4 = 350W

1
2
3

T1

PULSE

GND (-)

4-20 (+)

(+)

(-)

(+)

(-)

(+)

(-)

T4

3

1 2

(+)

FVS

SIG

(-)

RED (+)

BARE

BLACK (-)

3

1
2

T3

DRY

RMT

COM

3

1
2

T3

DRY

RMT

COM

(+)

(-)

(+)

(-)

2

1

FREQ.

(-)

(+)

T5

DIGITAL PULSE
RECEIVER CIRCUIT

1.5K OHM

(+)

(-)

EXTERNAL SOURCE
6-30V DC

1 2 3

N.C. COM. N.O.

RELAY

OUT

T7

NO

C

NC

SWITCH LOAD
6 AMP MAX @ 250V AC
5 AMP MAX @ 30V DC

2

3

1

GROUND

N EUTRAL

(COMMON)

LINE

(HOT)

T11

N.C.

COM

N.O.

T8

3

1
2

CC1

N.O.

COM

N.C.

CC2

T9

3

1
2

CC3

3

1
2

N.O.

COM

N.C.

T10

NO

C

NC

SWITCH LOAD
1 AMP MAX @ 125V AC
0.8 AMP MAX @ 30V DC

NO

C

NC

C

NC

NO

SWITCH LOAD
1 AMP MAX @ 125V AC
0.8 AMP MAX @ 30V DC

SWITCH LOAD
1 AMP MAX @ 125V AC
0.8 AMP MAX @ 30V DC

EXTERNAL DEVICE
6 TO 30V DC

OPEN CIRCUIT
IMPEDANCE MUST
BE GREATER THAN
50K OHM

BLUE-WHITE
FVS SENSOR

0-10V DC
TRANSMITTER
SOURCE

FREQUENCY
TRANSMITTER
SOURCE

ACTIVE 4-20mA
TRANSMITTER
SOURCE

2

1

4-20mA

(-)

(+)

T6

4-20mA RECEIVER
600 OHM LOAD MAX.

(+)

(-)

96 TO 264 VOLT AC,
50 / 60 HZ
A3 = 220W
A4 = 350W

Risk of electric shock - All
wiring must be insulated
and rated 300V minimum.

!

WARNING

Terminals T1 thru T10
Plug type
16 - 24 AWG

Power Input Terminal T11
Plug type
14 - 30 AWG

T4

T4

T4

1

2

3

(+) POSITIVE

SIGNAL

(-) NEGATIVE

T4

3

1 2

(+)

FVS

SIG

(-)

SIGNAL

NEGATIVE (-)

BLUE-WHITE
MICRO-FLO
FLOWMETER
PULSE OUTPUT

INPUT:
FVS SYSTEM
(FLOW VERIFICATION
SENSOR)
FS or FP MICRO-FLO
FLOWMETER ONLY

1
2
3

T1

PULSE

GND (-)

4-20 (+)

(OPTIONAL PUMP #2)

Single or dual pump (series)
input. Loop voltage must not
exceed 24 Volts.

Advertising