background image

Page 20

4.3.5

Pulse Batch (low speed pulse)

Used to remotely control pump with an incoming pulse signal. Can be used with
an external foot pedal, a water meter, a PLC, contact closure, or other low speed
pulse devices.

Default settings:

1 Pulse = 100% motor speed for 2.5 seconds

Press SELECT RUN MODE button until Pulse Batch is displayed in the top line
of the display.

To configure the pump, navigate to Pulse Batch menu by using short-cut
method described at beginning of section, or by pressing MENU button, then
selecting Input Setup, Input Modes, and then Pulse Batch.

Press UP or DOWN arrow to scroll through 0 - 9 on selected digit.

Press RIGHT arrow to scroll over to next digit to right. If you pass your desired
digit, you can easily scroll back by continuously pressing RIGHT button.

Press ENTER to save changes.

Continue this process until all four screens have been configured.

If you used short-cut to enter Pulse Batch setup, then just press and hold Select
Run Mode button until Run Mode screen is displayed.

If you used Menu button to navigate to Pulse Batch setup, you must navigate
back out of menu structure. To do this you must select <-Esc at bottom of every
screen menu until you see Run Mode screen displayed.

- Pulse Batch

% Motor Speed @ Batch:

% Motor during batch.

00.0%

1

- Pulse Batch

Input Pulse Number:

Pulse Number for batch

001

0

- Pulse Batch

Pump On Time:

Run time during batch.

02.5

0

Press ENTER to set.

Max = 999999.9 Seconds

Press ENTER to set.

In Pulse Batch mode, you can view current
incoming signal count by pressing RIGHT
arrow (see screen shot). RIGHT arrow is a
convenient way to scroll through multiple read-
only screens during normal operating mode of
pump.

Tip!

Pulse Batch

Pulse Number:

0

Run Time (SEC): 2.5

- Screen Shot -

Displays current incoming signal

In Frequency Input mode, you can view
current incoming signal by pressing RIGHT
arrow (see screen shot). RIGHT arrow is a
convenient way to scroll through multiple read-
only screens during normal operating mode of
pump.

Tip!

300

Frequency Input

Hz

Displays current incoming signal

- Screen Shot -

Е

Й

ДИ

Displays current rotor direction

Flex-Pro

Advertising
This manual is related to the following products: