Flex-pro, 0 output setup (alarm relays), Page 29 – Blue-White FLEX-PRO A4 ProSeries Peristaltic Pump User Manual

Page 29

Advertising
background image

Page 29

Flex-Pro

Note:
Contact #1 shown only. Contact #2, and
Contact #3 use the same menu items.

- Output Setup

+ Signal Output

+ Relay Output
+ Contact #1

+ Contact #2

Output - Signal

+ Contact #3

<- Esc

Hidden

Output - Assign Relay

- Output Setup

+ Signal Output Modes

+ Contact #1
+ Contact #2
+ Contact #3

<- Esc

+ Relay Output

- 4-20 mA Output

Signal @ min % Motor:

Input mA Signal
@ Min % Motor speed

- 4-20 mA Output

Minimum % Motor:

Input Min % Motor
for mA Signal Output

- 4-20 mA Output

Signal @ Max % Motor:

Input mA signal
@ Max % Motor Speed

- 4-20 mA Output

Maximum % Motor:

Input Maximum % Motor
for mA Signal output

- Relay Output

Both, TFD/FVS

FVS

4-20mA Mode

- Signal Output

4-20 mA Output
Freq. Output
Disable

- Signal Output

4-20 mA Output
Freq. Output
Disable

Done

Done

- Freq. Output

Signal @ Min % Motor:

Input Frequency (Hz)
@ Min % Motor Speed

000

0

- Freq. Output

Minimum % Motor:

Input Min % Motor
for Freq. output

00.0

0

- Freq. Output

Signal @ Max % Motor:

Input Frequency (Hz)
@ Max % Motor Speed

000

1

- Freq. Output

Maximum % Motor:

Input Maximum % Motor
for Freq. Output

00.0

1

Monitor Input
Monitor Output
Monitor Run/Fail
Manual Mode

- Output Setup

+ Signal Output Modes
+ Relay Output

+ Contact #2
+ Contact #3

<- Esc

+ Contact #1

- Contact Closure #1

Monitor Input
Monitor Output
Monitor Run/Fail

Both, TFD/FVS

Disable

TFD

Hidden

Hidden

Hidden

Hidden

Output -

Contact Closure #1

(select one)

(select one)

0

00.0

0

4.00

1

00.00

2

0.00

Pump Run/Stop

Frequency Mode

Cycle Timer Mode
Dispensing Mode
Manual Dosing
Prop. Dosing

0-10 VDC Mode

Pulse Mode

Disable

FVS

TFD

Pump Run/Stop

4-20mA Mode

Manual Mode

Frequency Mode

Cycle Timer Mode
Dispensing Mode
Manual Dosing Acive
Prop. Dosing Active

0-10 VDC Mode

Pulse Mode

Remote Active

Remote Active

Done

Done

Reverse Alarm
General Error

Reverse Alarm
General Error

+ Configuration

- Menu

+ Input Setup

+ Output Setup

<- Esc

+ Power Fail option

Description of Relay and Contact Closure Output triggers

Selection:

Contact energizes when:

Pump Run/Stop ........Motor turning (roller assembly is rotating).
Monitor Input .... ........Incoming analog or digital signal is not received or is out of range.
Monitor Output.. ........Outgoing analog or digital signal not transmitted or is out of range.
Monitor Run/Fail........Motor fails to respond to commands from the internal controller.
Both TFD/FVS .. ........Either TFD or FVS system triggers.
FVS ........ ........ ........After the programmed delay time, pulses are not received from flow sensor.
TFD ........ ........ ........Tube failure is detected by sensors in the head.
Active Mode...... ........The selected run mode is currently activated.
Remote Active .. ........Energized when Remote only is activated.
Reverse Alarm.. ........The motor revolution is reversed (turning clock-wise).
General Error.... ........A motor overload or other internal error has occurred.
Disable..... ........ ........Output alarm contact is disabled.

Relay Out Delay

Input Relay Delay:

Max Delay = 999.9 (s)
Press ENTER to set

0

00.0

Contact 1 Delay

Input Relay Delay:

Max Delay = 999.9 (s)
Press ENTER to set

0

00.0

5.0 Output Setup (alarm relays)