4.3.4

Frequency Input (Hz)

Used to remotely control pump with an incoming high speed frequency signal.
Typically used with flow meters or other external devices.

Default settings:

0 Frequency (Hz) = 0% motor speed
1000 Frequency (Hz) = 100% motor speed

Press SELECT RUN MODE button until Frequency Input is displayed in the
top line of the display.

To configure the pump, navigate to Frequency Input menu by using short-cut
method described at beginning of section, or by pressing MENU button, then
selecting Input Setup, Input Modes, and then Frequency Input.

Press UP or DOWN arrow to scroll through 0 - 9 on selected digit.

Press RIGHT arrow to scroll over to next digit to right. If you pass your desired
digit, you can easily scroll back by continuously pressing RIGHT button.

Press ENTER to save changes.

Continue this process until all four screens have been configured.

If you used short-cut to enter Frequency Input setup, then just press and hold
Select Run Mode button until Run Mode screen is displayed.

If you used Menu button to navigate to Frequency Input setup, you must
navigate back out of menu structure. To do this you must select <-Esc at bottom
of every screen menu until you see Run Mode screen displayed.

- Frequency Input

% Motor @ Min Signal:

Input % Motor Speed at
Minimum Freq. (Hz) Signal

00.0%

0

- Frequency Input

Min Frequency Signal:

Input Min. Freq. (Hz) signal

000

0

- Frequency Input

% Motor @ Max Signal:

Input % Motor Speed at
Maximum Freq. (Hz) Signal

00.0%

1

- Frequency Input

Max Frequency Signal:

Input Max. Freq. (Hz) signal

000

1

Press ENTER to set.

Press ENTER to set.

Injection
Point

S3 Series | Hybrid Ultrasonic Flowmeter

NEMA 4X

IP 66

Industries, Ltd.

ProSeries

by Blue-White Ind.

TM

Doppler /
Transit Time

Discharge

Line

Paddlewheel

Flow Sensor / Meter

Ultrasonic

Flow Meter

Injection
Point

Example #1, Ultrasonic flow meter

Example #2, Paddlewheel flow meter

Discharge

Line

or

0

200 400 600 800 1000

0

25

50

75

100

Pump

Motor Speed (%)

Frequency Input (Hz)

0 Hz = 0% Pump Output

1000 Hz = 100% Pump Output

0

25

50

75

100

0 Hz = 100% Pump Output

1000 Hz = 0% Pump Output

0

25

50

75

100

0 Hz = 20% Pump Output

800 Hz = 50% Pump Output

0%

Output

Pump

Motor Speed (%)

Pump

Motor Speed (%)

100%

Output

100%

Output

0%

Output

50%

Output

0

200 400 600 800 1000

0

200 400 600 800 1000

20%

Output

Frequency Input (Hz)

Frequency Input (Hz)

Examples: