4.3.3

0 - 10 VDC Input (Volt DC)

Used to remotely control pump with an incoming 0-10 VDC signal.

Default settings:

0 VDC = 0% motor speed
10 VDC = 100% motor speed

Press SELECT RUN MODE button until 0 - 10 VDC Input is displayed in the top
line of the display.

To configure the pump, navigate to 0 - 10 VDC Input menu by using short-cut
method described at beginning of section, or by pressing MENU button, then
selecting Input Setup, Input Modes, and then 0 - 10 VDC Input.

Press UP or DOWN arrow to scroll through 0 - 9 on selected digit.

Press RIGHT arrow to scroll over to next digit to right. If you pass your desired
digit, you can easily scroll back by continuously pressing RIGHT button.

Press ENTER to save changes.

Continue this process until all four screens have been configured.

If you used short-cut to enter 0 - 10 VDC Input setup, then just press and hold
Select Run Mode button until Run Mode screen is displayed.

If you used Menu button to navigate to 0 - 10 VDC Input setup, you must
navigate back out of menu structure. To do this you must select <-Esc at bottom
of every screen menu until you see Run Mode screen displayed.

- 0-10 VDC Input

% Motor @ Min Signal:

Input % Motor Speed at
Minimum Volt DC Signal

00.0%

0

- 0-10 VDC Input

Min VDC Signal:

Input Min. Volt DC signal

0.00

0

- 0-10 VDC Input

% Motor @ Max Signal:

Input % Motor Speed at
Max VDC Signal

00.0%

1

- 0-10 VDC Input

Max VDC Signal:

Input Max. Volt DC signal

0.00

1

Press ENTER to set.

Press ENTER to set.

In 0 - 10 VDC mode, you can view current
incoming signal by pressing RIGHT arrow (see
screen shot). RIGHT arrow is a convenient
way to scroll through multiple read-only
screens during normal operating mode of
pump.

Tip!

0-10 VDC Input

VDC

Displays current incoming signal

12.5

- Screen Shot -

Е

Й

ДИ

Displays current rotor direction

Example 1

0

2

4

6

8

10

0

25

50

75

100

Pump

Motor Speed (%)

VDC Input

from external source

0 VDC = 0% Pump Output

10 VDC = 100% Pump Output

Example 2

0

25

50

75

100

0 VDC = 100% Pump Output

10 VDC = 0% Pump Output

Example 3

0

25

50

75

100

0 VDC = 20% Pump Output

8 VDC = 45.3% Pump Output

0%

Output

Pump

Motor Speed (%)

Pump

Motor Speed (%)

100%

Output

100%

Output

0%

Output

45.3%

Output

0

2

4

6

8

10

VDC Input

from external source

0

2

4

6

8

10

VDC Input

from external source

20%

Output

0%

Output

100%

Output

100%

Output

0%

Output

50%

Output

20%

Output

Flex-Pro

Advertising
This manual is related to the following products: