Blue-White FLEX-PRO A4 ProSeries Peristaltic Pump User Manual

Page 28

Advertising
background image

Page 28

Flex-Pro

4.7

Remote/Local Control

The Flex-Pro can be configured for Remote control only, Local control only, or
either (disabled).

When set for Remote control only, all touch pad buttons except the menu button are
disabled. To completely lock out the menu, configure a password (see page 12,
section 8). If REMOTE ONLY is selected, the user is prompted to select an input
operating mode which must then be used when operating the pump.

When set for local control only, all input signals including the remote start/stop are
disabled. Note that the “contact closure input” menu setting (section 4.4) is
switched to “disabled” while LOCAL ONLY is selected. This menu setting will return
to the previous setting when REMOTE ONLY or DISABLED is selected.

- Input Setup

+ Input Modes
+ Contact Input
+ Set FVS

<- Esc

Hidden

+ Set Rev Alarm

+ Set TFD

+ Remote/Local

- Remote/Local

Remote Only
Local Only
Disable

Done

(select one)

- Remote Only Input Mode

4-20 mA
0-10 VDC
Frequency

(select one)

Hidden

Done

Proportional

Pulse

Removing the pump head
cover automatically puts
the pump into
“maintenance” mode,
allowing the operator to
replace the pump tube
without changing the
Remote/Local settings.

Tip!

MAINTENANCE MODE

Pump Cover Removed!

Press STOP to stop

- Cover was removed!
- Motor Speed = 6 RPM

MAINTENANCE MODE

Press START to run

4.8

Pump Tube Timer

Flex-Pro has a built in Pump Tube Timer. Timer starts when rotor is rotating and stops
when rotor is idle. To view current Pump Tube Timer value, press ENTER and DOWN
arrow at same time while in the normal operating mode.

Screen will display current Pump Tube Time in run-time hours. While displayed, press
ENTER button twice to reset Pump Tube Timer to zero.

+