Functional safety with NORD SK 200E frequency inverters

42

BU 0230 GB-2712

Size 4

FI type

SK 200E

SK 210E

SK 220E

SK 230E

(SH)

(ASI)

(SH+ASI)

Pin

Labelling

1

43

24V (internal, output max. 750mA)

2

43

24V (internal, output max. 750mA)

3

40

GND, reference potential for digital signals

4

40

GND, reference potential for digital signals

5

-/84

/

ASI+, AS interface

6

-/85

/

ASI-, AS interface

7

11

10V 
 Reference voltage

8

14

Analog input 1

9

16

Analog input 2

10

12

AGND, Reference potential for analog signals

11

44

24V, external 24V FI supply

12

44

24V, external 24V FI supply

13

40

GND, reference potential for digital signals

14

40

GND, reference potential for digital signals

15

21

DIN1 / digital input 1

16

22

DIN2 / digital input 2

17

23

DIN3, digital input 3

18

24/89

DIN4,

digital

input 4

24V SH,

“Safe
stop”„

DIN4,

digital

input 4

24V SH,

“Safe
stop”„

19

40/88

GND

GND SH

GND

GND SH

20

40

GND, reference potential for digital signals

21

1

DOUT1, digital output 1

22

40

GND

23

3

DOUT2, digital output 2

24

40

GND

25

77

SYS H, system bus +

26

78

SYS L, system bus -

27

38

TF+, motor PTC connection

28

39

TF-, motor PTC connection

Separate terminal block (2-pole):

1

79

MB+, electromagnetic brake control

2

80

MB-, electromagnetic brake control

NOTE

GND is a common reference potential for digital inputs and outputs and for the 24V supply of
the frequency inverter.

The labelling of the control terminal bar differs according to the SK 200E version.