NORD Drivesystems BU0230 User Manual

Page 55

Advertising
background image

4 Parameterisation

BU 0230 GB-2712

55

Parameter

Setting value / Description / Note

Device

Supervisor

Parameter
set

Note

SimpleBox: with the Simplebox only warning messages and errors can be displayed. Display of
the messages is in encoded form. For the description of the codes (warning/error numbers),
please refer to the tables in BU 0200.

ParameterBox: with the ParameterBox the messages are displayed in plain text.. In addition, the
reason for a possible disabling of starting can also be displayed.

Bus: The display of bus-level error messages is made in decimal integer format. If this value is
divided by 10, the display corresponds to that which is listed in BU 0200.

Example: Display: 20

→ Error number 2.0

P701

[-01]

...

[-05]

Last fault 1...5

0.0 ... 21.4

This parameter stores the last 5 faults. Further details in Section 9.3 .

With the SimpleBox the corresponding memory location 1...5 (Array parameter), must be
selected and confirmed with the ENTER key in order to read the stored error code.

Advertising