5.3 OSSD outputs, test pulse

t

off

≤ 0.5ms (width of test pulse)

Maximum time for which the output of the safety switching device is switched off for test purposes.

D

≥ 90% (Duty)

The supply voltage is applied for at least 90% of the time. I.e. for a test pulse of t

off

=0.5 ms the supply

voltage is subsequently applied for at least t

on

=4.5 ms.

Double pulses are permitted when the two pulses are at least 1ms apart and the condition for D is
observed.

zulässige Testpulse eines OSSD

0

1

-1

0

1

2

3

4

5

6

7

8

9

10

11

Zeit in ms

The following sequence results at maximum pulse width: First test pulse, where t

off

= 0.5 ms, the supply

voltage is then connected for 0.5 ms, followed by the second test pulse where t

off

= 0.5 ms, and then the

supply voltage is connected for at least 8.5 ms!