4 Communication

4.1 Process data

Control words and setpoints are transferred from the bus master / controller to the SK TU3-…bus module as
process data and in return, the status word and actual values are sent to the bus master / controller from the
FI. Transfer is carried out cyclically. The bus master / controller can access these process values directly, as
they are stored in the I/O area.
The length and structure of the process data is specified via the PPO types during the planning of the
PROFINET network.

The allocation of the values transferred in the setpoint/actual value area of the FI is made via the
parameters P543 to P548 or P543 [-01]…[-05].


4.1.1

Process data structure

The structure of the process data is defined by the PPO type.

4.1.1.1

Pure process data communication

Direction of

transmission

Transmitted data

( 4 Byte )

1st

word

2nd

word

... to SK TU3

Control word

Setpoint 1

... from the SK TU3

Status word

Actual value 1

Table 9: PPO 3

Direction of

transmission

Transmitted data

( 8 Byte )

1st word

2nd word

3rd word

4th word

... to SK TU3

Control word

Setpoint 1

Setpoint 2

Setpoint 3

... from the SK TU3

Status word

Actual value 1 Actual value 2 Actual value 3

Table 10: PPO 4

Direction of

transmission

Transmitted data

( 12 Byte )

1st word

2nd word

3rd word

4th word

5th word

6th word

... to SK TU3

Control word

Setpoint 1

Setpoint 2

Setpoint 3

Setpoint 4

Setpoint 5

... from the SK TU3

Status word

Actual value 1 Actual value 2 Actual value 3 Actual value 4 Actual value 5

Table 11: PPO 6