5 Parameter

5.1 Parametersiation of PROFINET bus module SK TU3-PNT

The following parameters affect the bus modules.

5.1.1

BUS module standard parameters (P15x)

Access:

Read/Write

Parameter

{Factory setting}

Setting value / Description / Note

Device

Parameter
type

P152

Factory setting

(Factory setting)

SK TU3-PNT

16 bit

0 ...1

{ 0 }

By selecting the appropriate value and confirming it with the ENTER key, the selected
parameter range is entered in the factory setting. Once the setting has been made, the value of
the parameter returns automatically to 0.

0 = No change:

Does not change the parameterisation.

1 = Load factory settings:

The complete parameterisation of the FI is reset to the factory

setting. All originally parameterised data are lost.


5.1.2

Parameters specific to PROFINET BUS modules (P16x)

Access:

Read/Write

Parameter

{Factory setting}

Setting value / Description / Note

Device

Parameter
type

P160 …

[-01]


[-04]

IP address

(IP address)

SK TU3-PNT

8 Bit

Parameterised IP address consisting of four bytes. In case of a change to the IP address (e.g.
with NORD CON), this is only saved by writing it to Index 4.

CAUTION:

Saving is prevented if the IP address which is entered does not correspond to the

convention. If there are contradictions between the IP address and the mask (P161), the mask
is corrected automatically.

Deletion of the IP settings (IP+sub-net mask) is performed by entering IP 0.0.0.0.

0 ... 255

{ [-01] = 192 }

{ [-02] = 168 }

{ [-03] = 20 }

{ [-04] = 200 }

[-01] =

IP High (NET-ID)

[-02] =

IP (NET-ID)

[-03] =

IP (NET ID)

[-04] =

IP Lo (Host)

P161

[-01]

[-04]

IP sub-net mask

(IP sub-net mask)

SK TU3-PNT

8 Bit

0 ... 255

{ [-01] = 255 }

{ [-02] = 255 }

{ [-03] = 255 }

{ [-04] = 0 }

Parameterised IP mask consisting of four bytes. In case of a change to the IP mask (e.g. with
NORD CON), this is only saved by writing it to Index 4.

ATTENTION:

Saving is prevented if the entered IP address is inconsistent with the IP address.

Example:

IP-Add: 192.168.20.200, IP mask: 255.255.255.0  Correct

IP-Add: 192.168.20.200, IP mask: 255.0.0.0

Error