NORD Drivesystems BU0590 User Manual

Page 39

Advertising
background image

Fehler! Verweisquelle konnte nicht gefunden werden.Fehler! Verweisquelle konnte nicht gefunden werden.

BU 0590 GB-0312

Subject to technical amendments

39

Parameter

{Factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter set

P543

Bus actual value 1

(Actual bus value 1)

up to

SK 535E

S P

0 ... 24

{ 1 }

The return value 1 can be selected for bus actuation in this parameter.

The possible analog functions can be found in the following table.

NOTE:

For further details please refer to the manual BU0500 (P418, P543), the relevant
Bus operating manual or the supplementary POSICON manual BU0510.

P543 [-01]
...
[-05]

Bus actual value

(Actual bus values)

SK 540E and

above

S P

In this parameter the return value for bus actuation can be selected.

NOTE:

The actual values 4 and 5 must be supported by the relevant bus module. For
further details please refer to the manual BU0500 (P418, P543), the relevant BUS
operating manual, the supplementary POSICON manual BU0510 or the
supplementary PLC manual BU0550.

[-01] =

Actual bus value 1

[-02] =

Actual bus value 2

[-03] =

Actual bus value 3

[-04] =

Actual bus value 4

[-05] =

Actual bus value 5

0 ... 57

{ [-01] = 1 }
{ [-02] = 4 }
{ [-03] = 9 }
{ [-04] = 0 }
{ [-05] = 0 }

0 =

Off

1 =

Actual frequency

2 =

Actual speed

3 =

Electricity

4 =

Torque current (100% = P112)

5 =

Digital IO status

1

6 =

... 7 Reserved

8 =

Setpoint frequency

9 =

Error number

10 =

... 11 Reserved

12 =

BusIO Out Bits 0...7

13 =

... 16 Reserved

17 =

Value analog input 1

18 =

Value analog input 2

19 =

Setpoint frequency master value
(P503)

20 =

Set Freq. After Ramp "Setpoint
frequency master value after ramp"

21 =

Act. Freq. w/o Slip "Actual frequency
without slip master value"

22 =

Speed encoder

(only possible with SK 520E and
encoder feedback)

23 =

Act. freq. with slip, "Actual frequency
with slip" (SW V2.0 and above)

24 =

Lead.act.freq.+slip, "Master value,
actual frequency with slip" (SW V2.0
and above)

53 = ... 57 Reserved

P544

Bus actual value 2

(Actual bus value 2)

up to

SK 535E

S P

0 ... 24

{ 0 }

This parameter is identical to P543.

Condition is PPO 2 or PPO 4 type (P507).

1

The assignment of the digital inputs in P543/ 544/ 545 = 5

Bit 0 = DigIn 1

Bit 1 = DigIn 2

Bit 2 = DigIn 3

Bit 3 = DigIn 4

Bit 4 = DigIn 5

Bit 5 = DigIn 6 (SK 520E and above) Bit 6 = DigIn 7 (SK 520E and above)

Bit 7 = Dig. func. AIN1

Bit 8 = Dig. func. AIN2 Bit 9 = DigIn 8 (SK 540E and above) Bit 10 = DigIn 1, 1st IOE (SK 540E and above) Bit 11 = DigIn 2, 1st IOE

(SK 540E and above)

Bit 12 = Out 1/ MFR1 Bit 13 = Out 2/ MFR2

Bit 14 = Out 3/ DOUT1 (SK 520E and above) Bit 15 = Out 4/ DOUT2

(SK 520E and above)

Advertising