2 Modules

BU 0590 GB-0312

Subject to technical amendments

9

2.2 PROFINET - BUS Module

2.2.1

Mounting

The technology units must be installed as follows:

1. Switch off the mains voltage (frequency inverter), observe the waiting period.

2. Push the control terminals cover down slightly or remove.

3. Remove the blank cover by pressing the release on the lower edge and pulling off with an upward

turning movement. If necessary, the fixing screw next to the release must be removed.

4. Hook the technology unit onto the upper edge slots and press in lightly until engaged. Ensure full

contact with the connector strip and fasten with the screws if necessary (separate packet).

5. Close the control terminal cover again.

1

4

Similar to illustration

3

2 „press“

Fig. 3 Installation of the Technology Unit (optional module)

Further detailed information can be found in the device manual BU 0500.

-