Commands & communication frames, 3 commands & communication frames – PNI TCM 5 User Manual

Page 32

Advertising
background image

PNI Sensor Corporation

Doc #1007537 r12

TCM3 & TCM5 User Manual- Sept 2011

Page 32

Boolean

Boolean is a 1-byte parameter that MUST have the value 0 (false) or 1 (true).

byte

7

0

4.3.3 Commands & Communication Frames


Overview:

Frame
ID

Command

Description

1

kGetModInfo

Queries the modules type and firmware revision number.

2

kModInfoResp

Response to kGetModInfo

3

kSetDataComponents

Sets the data components to be output.

4

kGetData

Queries the module for data

5

kDataResp

Response to kGetData

6

kSetConfig

Sets internal configurations in the module

7

kGetConfig

Queries the module for the current internal configuration value

8

kConfigResp

Response to kGetConfig

9

kSave

Commands the module to save internal and user calibration

10

kStartCal

Commands the module to start user calibration

11

kStopCal

Commands the module to stop user calibration

12

kSetParam

Sets the FIR filter settings for the magnetometer & accelerometer
sensors.

13

kGetParam

Queries for the FIR filter settings for the magnetometer &
accelerometer sensors.

14

kParamResp

Contains the FIR filter settings for the magnetometer &
accelerometer sensors.

15

kPowerDown

Used to completely power-down the module

16

kSaveDone

Response to kSave

17

kUserCalSampCount

Sent from the module after taking a calibration sample point

18

kUserCalScore

Contains the calibration score

19

kSetConfigDone

Response to kSetConfig

20

kSetParamDone

Response to kSetParam

21

kStartIntervalMode

Commands the module to output data at a fixed interval

22

kStopIntervalMode

Commands the module to stop data output at a fixed interval

23

kPowerUp

Sent after wake up from power down mode

24

kSetAcqParams

Sets the sensor acquisition parameters

25

kGetAcqParams

Queries for the sensor acquisition parameters

26

kAcqParamsDone

Response to kSetAcqParams

27

kAcqParamsResp

Response to kGetAcqParams

28

kPowerDownDone

Response to kPowerDown

29

kFactoryUserCal

Clears user calibration coefficients

30

kFactorUserCalDone

Response to kFactoryUserCal

31

kTakeUserCalSample

Commands the unit to take a sample during user calibration