PNI TCM 5 User Manual

Page 36

Advertising
background image

PNI Sensor Corporation

Doc #1007537 r12

TCM3 & TCM5 User Manual- Sept 2011

Page 36

1

10.0

Declination ID

Declination

Angle

(Float32)

Configuration Identifiers

Settings

Configuration
ID

Format

Units/ Range

Default
Values

kDeclination

1

Float32

-

180˚ to 180˚

kTrueNorth

2

Boolean

True or False

False

kBigEndian

6

Boolean

True or False

True

kMountingRef

10

UInt8

1 = Standard
2 = X axis up
3 = Y axis up
4 = -90° heading offset
5 = -180° heading offset
6 = -270° heading offset
7 = Z down
8 = X + 90°
9 = X + 180°
10 = X + 270°
11 = Y + 90°
12 = Y + 180°
13 = Y + 270°
14 = Z down + 90°
15 = Z down + 180°
16 = Z down + 270°

1

kUserCalStableCheck

11

Boolean

True or False

True

kUserCalNumPoints

12

UInt32

12

– 50

50

kUserCalAutoSampling

13

Boolean

True or False

True

kBaudRate

14

UInt8

0

– 300

1

– 600

2

– 1200

3

– 1800

4

– 2400

5

– 3600

6

– 4800

7

– 7200

8

– 9600

9

– 14400

10

– 19200

11

– 28800

12

– 38400

13

– 57600

14 - 115200

12


kDeclination

This sets the declination angle to determine True North heading. Positive declination is

easterly declination and negative is westerly declination. This is not applied until TrueNorth is set to
true.

kTrueNorth Flag to set compass heading output to true north heading by adding the declination angle to
the magnetic north heading.

kBigEndian Flag to set the Endianness of packets

kMountingRef This sets the reference orientation for the module.

Advertising
This manual is related to the following products: