Sensor Heating (RoHumiHeat), Value-Dependent

The sensor heating can be activated on the basis of definable temperature/humidity values.

Below a definable temperature threshold value

Above a definable temperature threshold value

Below a definable humidity threshold value

Above a definable humidity threshold value

The sensor heating is then activated as long as the measured temperature or humidity is below or above the

threshold value defined.

The temperature of the humidity sensor can be selected freely between 0.1 °C and 10 °C above ambient

temperature.

ROTRONIC offers the value-dependent heating function for applications in which value-dependent heating

suffices. Please note, however, that condensation could form on the sensor in an unheated state. If

condensation does form on the sensor when it is in operation, it can only be removed reliably with the

RoHumiClean function (five minutes cleaning at 150 °C).

Temperature differences of more than 3 °C between the sensor and environs caused by heating can have

effects on the external temperature measurement. This is particularly possible in stagnant air because the

heat energy is then not dissipated efficiently.

The start and stop responses follow the general function description above. The function "value-dependent

sensor heating" can be enabled/disabled with the HW4 software.