6.4 Cable Connection with Open Ends

Wire Colour

Name

Function

Green

V (+)

5…24 VDC

15…24 VDC, depending on output variant and functions used

Grey / Shield

GND

Supply ground

Yellow

AGND

Analog GND

Brown

OUT2, analog

Temperature (default setting: -

40…60 °C)

Red

RS-485 +

RS-485 TX+ / RX+

White

OUT1, analog

Humidity (default setting: 0…100 %RH)

Blue

RS-485 -

RS-485 TX- / RX-