24 v – Amana Gas Furnance S)8 User Manual

Page 19

Advertising
background image

19

G

AS

S

UPPLY

AND

P

IPING

24 V

AC

H

UMIDIFIER

The yellow wire connected to the I.D. Blower pressure switch

is powered anytime the pressure switch is closed and

provides 24 VAC humidifier control. Remove the yellow wire

and connect the supplied brown jumper wire to the pressure

switch terminal. Reconnect the yellow wire to the “piggyback”

terminal on the brown jumper and then connect the 24 VAC

line of the humidifier to the stripped end of the brown wire.

Using a wire nut or a field-supplied quick connect terminal

can make this connection. The wiring must conform to all

local and national codes. Connect the COM side of the

humidifier to the B/C terminal on the furnace control board

(or to the COM side of the 24 VAC transformer). DO NOT
CONNECT 115V HUMIDIFIER TO THESE TERMINALS.

G

AS

S

UPPLY

AND

P

IPING

The furnace rating plate includes the approved furnace gas in-
put rating and gas types. The furnace must be equipped to
operate on the type of gas applied. This includes any conver-
sion kits required for alternate fuels and/or high altitude.

CAUTION

T

O

 

PREVENT

 

UNRELIABLE

 

OPERATION

 

OR

 

EQUIPMENT

 

DAMAGE

THE

 

INLET

 

GAS

 

SUPPLY

 

PRESSURE

 

MUST

 

BE

 

AS

 

SPECIFIED

 

ON

 

THE

 

UNIT

 

RATING

 

PLATE

 

WITH

 

ALL

 

OTHER

 

HOUSEHOLD

 

GAS

 

FIRED

 

APPLIANCES

 

OPERATING

.

Inlet gas supply pressures must be maintained within the ranges
specified in the following table. The supply pressure must be
constant and available with all other household gas fired appli-
ances operating. The minimum gas supply pressure must be
maintained to prevent unreliable ignition. The maximum must
not be exceeded to prevent unit overfiring.

Natural Gas

Minimum: 5.0" w.c.

Maximum:10.0" w.c.

Propane Gas Minimum: 11.0" w.c.

Maximum:13.0" w.c.

Inlet Gas Supply Pressure

NOTE: Adjusting the minimum supply pressure below the limits
in the above table could lead to unreliable ignition. Gas input to
the burners must not exceed the rated input shown on the
rating plate. Overfiring of the furnace can result in premature
heat exchanger failure. Gas pressures in excess of 13 inches
water column can also cause permanent damage to the gas
valve.
At all altitudes, the manifold pressure must be within 0.3 inches
w.c. of that listed in the Specification Sheet applicable to your
model for the fuel used. At all altitudes and with either fuel, the
air temperature rise must be within the range listed on the fur-
nace nameplate. Should this appliance be converted to LP,
refer to the instructions included in the factory authorized LP
conversion kit.

H

IGH

A

LTITUDE

D

ERATE

IMPORTANT NOTE: The furnace will naturally derate itself with
altitude. Do not attempt to increase the firing rate by changing
orifices or increasing the manifold pressure. This can cause
poor combustion and equipment failure.

High altitude installations may require both a pressure switch
and an orifice change. These changes are necessary to com-
pensate for the natural reduction in the density of both the gas
fuel and the combustion air at higher altitude.

For installations above 7000 feet, please refer to your distribu-
tor for required kit(s).

Contact the distributor for a tabular listing of appropriate
manufacturer’s kits for propane gas and/or high altitude instal-
lations. The indicated kits must be used to insure safe and
proper furnace operation. All conversions must be performed
by a qualified installer, or service agency.

P

ROPANE

G

AS

C

ONVERSION

WARNING

P

OSSIBLE

 

PROPERTY

 

DAMAGE

PERSONAL

 

INJURY

 

OR

 

DEATH

 

MAY

 

OCCUR

 

IF

 

THE

 

CORRECT

 

CONVERSION

 

KITS

 

ARE

 

NOT

 

INSTALLED

. T

HE

 

APPROPRIATE

 

KITS

 

MUST

 

BE

 

APPLIED

 

TO

 

ENSURE

 

SAFE

 

AND

 

PROPER

 

FURNACE

 

OPERATION

. A

LL

 

CONVERSIONS

 

MUST

 

BE

 

PERFORMED

 

BY

 

A

 

QUALIFIED

 

INSTALLER

 

OR

 

SERVICE

 

AGENCY

.

This unit is configured for natural gas. The appropriate
manufacturer’s propane gas conversion kit, must be applied for
propane gas installations. Refer to the “Propane Gas and/or
High Altitude Installations” section for details.

Models using Single Stage Gas Valves

Altitude

Gas

Kit

Orifice

Manifold

Pressure

Pressure

Switch

#55

10.0" w.c.

NOTE: In Canada, gas furnaces are certified to 4500 feet.
NOTE: GMS81405DN** models utilize #43 orifices in Natural gas
applications.

0-7000

Natural

None

#45

3.5" w.c.

None

Propane

LPT-03

Models using 2-Stage Gas Valves

High

Stage

Low

Stage

Natural

None

#45

3.5" w.c. 1.9" w.c.

None

Propane

LPM-06

#55

10.0" w.c. 6.0" w.c.

None

0-7000

NOTE: In Canada, gas furnaces are only certified to 4500 feet.
NOTE: GMH81405DN** models utilize #43 orifices in Natural gas
applications.

Gas

Altitude

Kit

Orifice

Manifold Pressure Pressure

Switch

Change