Amana Gas Furnance S)8 User Manual

Page 7

Advertising
background image

7

P

RODUCT

A

PPLICATION

Air filters are installed in the system and maintained
during construction, replaced as appropriate during
construction, and upon completion of construction are
replaced.

The input rate and temperature rise are set per the
furnace rating plate.

100% outside air is provided for combustion air
requirements during construction. Temporary ducting
can be used.
NOTE: Do not connect the temporary duct directly to
the furnace. The duct must be sized according to the
instructions under Combustion and Ventilation Air
Requirements, Section 5.3.3.

The furnace heat exchanger, components, duct
system, air filters and evaporator coils are thoroughly
cleaned following final construction clean up.

All furnace operating conditions (including ignition, input
rate, temperature rise and venting) are verified
according to these installation instructions.

NOTE: The Commonwealth of Massachusetts requires that the
following additional requirements must also be met:

Gas furnaces must be installed by a licensed plumber
or gas fitter.

A T-handle gas cock must be used.

If the unit is to be installed in an attic, the passageway
to and the service area around the unit must have
flooring.

T

O

 

PREVENT

 

PROPERTY

 

DAMAGE

PERSONAL

 

INJURY

 

OR

 

DEATH

 

DUE

 

TO

 

FIRE

DO

 

NOT

 

INSTALL

 

THIS

 

FURNACE

 

IN

 

A

 

MOBILE

 

HOME

TRAILER

OR

 

RECREATIONAL

 

VEHICLE

.

WARNING

To ensure proper furnace operation, install, operate and
maintain the furnace in accordance with these installa-
tion and operation instructions, all local building codes
and ordinances.
In their absence, follow the latest edition of
the National Fuel Gas Code (NFPA 54/ANSI Z223.1), and/or
CAN/CSA B149 Installation Codes, local plumbing or waste
water codes, and other applicable codes.

A copy of the National Fuel Gas Code (NFPA 54/ANSI Z223.1)
can be obtained from any of the following:

American National Standards Institute

1430 Broadway

New York, NY 10018

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley

Cleveland, OH 44131

To register your Goodman

®

brand unit, go to

www.goodmanmfg.com and click “Warranty Registration”.
Complete the registration as prompted.

To register your Amana

®

brand unit, go to www.amana-hac.com

and click “Warranty Registration”. Complete the registration
as prompted.

Product limited warranty certificates for models currently in pro-
duction can be viewed at www.goodmanmfg.com or www.amana-
hac.com. If your model is not currently in production or does
not appear on the website, please contact your installing con-
tractor or contact customer service (877-254-4729) to obtain a
copy of your warranty certificate.

Each product overview page contains a Product Warranty link;
by clicking on it you will be able to view the limited warranty
coverage for that specific product. To view warranty registration
information, click on the Product Warranty text on the left navi-
gation panel on the home page of each website. The Online
Product Registration pages are located in this same section.

P

RODUCT

A

PPLICATION

This furnace is primarily designed for residential home-heating
applications. It is NOT designed or certified for use in mobile
homes, trailers or recreational vehicles. Neither is it designed
or certified for outdoor applications. The furnace must be in-
stalled indoors (i.e., attic space, crawl space, or garage area
provided the garage area is enclosed with an operating door).

This furnace can be used in the following non-industrial com-
mercial applications:

Schools, Office buildings, Churches, Retail stores,

Nursing homes, Hotels/motels, Common or office areas

In such applications , the furnace must be installed with the
following stipulations:

It must be installed per the installation instructions
provided and per local and national codes.

It must be installed indoors in a building constructed
on site.

It must be part of a ducted system and not used in a
free air delivery application.

It must not be used as a “make-up” air unit.

All other warranty exclusions and restrictions apply.

This furnace may be used as a construction site heater ONLY
if the following conditions are met:

The vent system is permanently installed per these
installation instructions.

A room thermostat is used to control the furnace. Fixed
jumpers that provide continuous heating CANNOT be
used.

Return air ducts are provided and sealed to the furnace.

A return air temperature range between 60ºF (16ºC)
and 80ºF (27ºC) is maintained.

Advertising
This manual is related to the following products: