Gme8 w, Iring, Iagram – Amana Gas Furnance S)8 User Manual

Page 44

Advertising
background image

44

GME8 W

IRING

D

IAGRAM

H

IG

H

V

O

LTA

G

E

!

D

IS

CO

NNE

CT

AL

L

PO

WER

BE

F

O

RE

SE

R

V

IC

IN

G

OR

IN

S

T

A

LLI

N

G

TH

IS

UNI

T

.

M

U

LTI

P

L

E

PO

WER

S

O

U

RCE

S

MA

Y

BE

PR

E

S

EN

T

. F

AIL

U

RE

TO

DO

SO

MA

Y

CAU

S

E

PR

O

P

E

R

T

Y

DAM

AG

E

,

P

E

RS

O

NAL

INJ

URY

OR

DE

AT

H

.

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

BK
(H

I)

AUXILIARY

PROPERLY POLARIZED AND GROUNDED.

SERVICING.WIRING TO UNIT MUST BE

WARNING:DISCONNECT POWER BEFORE

XFMR

BK

115V

24V

BR

LIMITS

WH
(N

)

RD
(M
E

D

LO
W

)

OR
(M

E

D

)

BL
(M

E

D

HI

)

BL
O

W

E

R

C

IRC
UL
AT

O

R

24V

THER

M

O

S

TA

T

C

O

NNEC

T

IO

NS

RO2 (11)

LIMIT

GND (8)

HUMIDIFIER

XFMR (6)

GND

G

C

W

Y

TO

MICRO

R

MVL (2)

MVC (9)

AUXILIARY

LIMIT CONTROLS

PS (10)

PSO (4)

HLI (7)

HLO (1)

CONTROL MODULE

INTEGRATED

NO

SWITCH

PRESSURE

ID BLOWER

VALVE

M1

GAS

C2

C

AUTO RESET

PRIMARY

MANUAL RESET ROLLOUT

LIMIT CONTROL(S)

115 VAC

FLAME SENSOR

FP

XFMR-H

XFMR (3)

RO1 (5)

24 VAC

HOT SURFACE

IGNITER

IN

TE

G

R

AT

E

D

CO
N

T

RO
L MO
D

U

LE

COOL-H

IGN

IND

ID

BLWR

CIRCULATOR

HE

AT-

H

BLWR

TRANSFORMER

40 VA

CONTROL

XFMR-N

IN

T

E

G

R

A

TE

D

CO
N

T

R

O

L MO
D

U

LE

CIR-N

0140F00658 REV. A

ON SOME MODELS

HUMIDIFIER

24 VAC

INDUCED DRAFT

BLOWER COMPARTMENT

BURNER COMPARTMENT

INTEGRATED CONTROL

INTERNAL TO

BLOWER

PRIMARY LIMIT

WH

GR

BK

IGNITER

SURFACE

HOT

PU

RD

15 PIN PLUG

C

NO

SWITCH

PRESSURE

BR

SENSOR

FLAME

BK

WH

ROLLOUT LIMITS

RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND

SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)

7 FLASHES = LOW FLAME SIGNAL

5 FLASHES = FLAME SENSE WITHOUT GAS VALVE

4 FLASHES = OPEN HIGH LIMIT

3 FLASHES = PRESSURE SWITCH STUCK OPEN

2 FLASHES = PRESSURE SWITCH STUCK CLOSED

STEADY ON = NORMAL OPERATION

OFF = CONTROL FAILURE

5

1 FLASH =

0

1

2

3

4

PU

6 FLASHES =

OPEN ROLLOUT OR OPEN FUSE

COLOR CODES:

PU PURPLE

OR ORANGE

YL YELLOW

6

7

8

BK BLACK

GR GREEN

BR BROWN

PK PINK

RD RED

GY GRAY

BL BLUE

WH WHITE

PU

OVERCURRENT PROTECTION DEVICE

JUNCTION BOX

MUST BE

WARNING:

SWITCH

WIRING TO UNIT

BEFORE SERVICING.

DISCONNECT POWER

LINE-H

DOOR

AND GROUNDED.

POLARIZED

PROPERLY

L

GND

LINE-N

DISCONNECT

N

SWITCH (TEMP.)

FIELD SPLICE

SWITCH (PRESS.)

PROT. DEVICE

OVERCURRENT

EQUIPMENT GND

TERMINAL

JUNCTION

HI VOLTAGE FIELD

HI VOLTAGE (115V)

LOW VOLTAGE FIELD

LOW VOLTAGE (24V)

PLUG CONNECTION

IGNITER

FIELD GND

IND-N

IGN-N

JUNCTION

BOX

OVERCURRENT PROTECTION

POWER SUPPLY WITH

TO 115 VAC/ 1/60HZ

GND

LINE-N

LINE H

DEVICE

DOOR SWITCH

WH

BK

SWITCH LOCATED IN BLOWER
COMPARTMENT ON SOME MODELS

RD

RD

BL

PU

YL

OR

BR

(SINGLE CONTROL ON SOME MODELS)

(SINGLE CONTROL ON SOME MODELS)

DI

A

G

NO
S

T

IC

LE
D

LO
HE
A

T

-H

PARK

SEE NOTE 6

CO
O

L

-H

HI

HE
A

T

-H

9

7

8

6

5

4

12

C

G

R

W

Y

5 MIN

2 STG

100 SEC

1 STG

AUTO

150 SEC

MODE

2N

D S

TG

DL

Y

HT O

FF DL

Y

2

1

EAC-H

LINE-H

XFMR-H

LI

N

E

NE
UT
R

A

L

FS

11

10

3

2

1

CONTROL MODULE

INTEGRATED

FUSE

PM

1

HI

C

2

3

2 STAGE

GAS VALVE
(HONEY WELL)

WH

24 VAC

HUMIDIFIER

RD

HI

MVH (12)

HI

LO

HE

AT-

H

AIR CLEANER

ELECTRONIC

EAC-N

EAC-H

WH

BL

BR

WH

BL

BK

BK

YL

YL

RD

YL

YL

PU

OR

WH

WH

WH

WH

YL

BL

RD

C

8 FLASHES = CHECK IGNITER OR IMPROPER GROUND

NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH
WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 °C. USE COPPER

CONDUCTORS ONLY.

4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO
PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR
FLOW CHART)
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS
WHILE IN STANDBY(NO THERMOSTAT INPUTS).