M,d)h8 w, Iring, Iagram – Amana Gas Furnance S)8 User Manual

Page 45

Advertising
background image

45

*(M,D)H8 W

IRING

D

IAGRAM

CA
P

BK(HI)

AUXILIARY

PROPERLY POLARIZED AND GROUNDED.

SERVICING.WIRING TO UNIT MUST BE

WARNING:DISCONNECT POWER BEFORE

XFMR

BK

115V

24V

BR

LIMITS

WH(N

)

RD(LOW

)

OR(ME

D

LOW)

B

L(M

ED)

BLO

W

ER

C

ICULA

T

OR

24

V

T

HERM

OST

A

TC
ONNEC

TIONS

RO2 (11)

LIMIT

GND (8)

HUMIDIFIER

XFMR (6)

GND

G

C

W

Y

TO

MICRO

R

MVL (2)

MVC (9)

AUXILIARY

LIMIT CONTROLS

PS (10)

PSO (4)

HLI (7)

HLO (1)

CONTROL MODULE

INTEGRATED

NO

SWITCH

PRESSURE

ID BLOWER

VALVE

M1

GAS

C2

C

AUTO RESET

PRIMARY

MANUAL RESET ROLLOUT

LIMIT CONTROL(S)

115 VAC

FLAME SENSOR

FP

XFMR-H

XFMR (3)

RO1 (5)

24 VAC

HOT SURFACE

IGNITER

INT
E

GRA

T

EDCON

T

ROL

MOD

ULE

BR

BR

COOL-H

IGN

IND

ID

BLWR

CIRCULATOR

HE

AT-

H

BLWR

TRANSFORMER

40 VA

CONTROL

XFMR-N

INTE

GRA

TEDCON

T

ROL

MODU

LE

CIR-N

0140F00662 REV. A

5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

ON SOME MODELS

HUMIDIFIER

24 VAC

INDUCED DRAFT

°C. USE COPPER CONDUCTORS ONLY.

BLOWER COMPARTMENT

BURNER COMPARTMENT

REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE

CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR FLOW CHART)

REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE

4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION

INTEGRATED CONTROL

INTERNAL TO

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

BLOWER

PRIMARY LIMIT

WH

GR

BK

IGNITER

SURFACE

HOT

PU

RD

15 PIN PLUG

C

NO

SWITCH

PRESSURE

BR

SENSOR

FLAME

BK

WH

ROLLOUT LIMITS

RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND

SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)

7 FLASHES = LOW FLAME SIGNAL

5 FLASHES = FLAME SENSE WITHOUT GAS VALVE

4 FLASHES = OPEN HIGH LIMIT

3 FLASHES = PRESSURE SWITCH STUCK OPEN

2 FLASHES = PRESSURE SWITCH STUCK CLOSED

STEADY ON = NORMAL OPERATION

OFF = CONTROL FAILURE

5

1 FLASH =

0

1

2

3

4

PU

6 FLASHES = OPEN ROLLOUT OR OPEN FUSE

COLOR CODES:

PU PURPLE

OR ORANGE

YL YELLOW

6

7

8

BK BLACK

GR GREEN

BR BROWN

PK PINK

RD RED

GY GRAY

BL BLUE

WH WHITE

PU

RATING OF AT LEAST 105

NOTES:

OVERCURRENT PROTECTION DEVICE

JUNCTION BOX

MUST BE

WARNING:

SWITCH

WIRING TO UNIT

BEFORE SERVICING.

DISCONNECT POWER

LINE-H

DOOR

AND GROUNDED.

POLARIZED

PROPERLY

L

GND

LINE-N

DISCONNECT

N

SWITCH (TEMP.)

FIELD SPLICE

SWITCH (PRESS.)

PROT. DEVICE

OVERCURRENT

EQUIPMENT GND

TERMINAL

JUNCTION

HI VOLTAGE FIELD

HI VOLTAGE (115V)

LOW VOLTAGE FIELD

LOW VOLTAGE (24V)

PLUG CONNECTION

IGNITER

FIELD GND

IND-N

IGN-N

JUNCTION

BOX

OVERCURRENT PROTECTION

POWER SUPPLY WITH

TO 115 VAC/ 1/60HZ

GND

LINE-N

LINE H

DEVICE

DOOR SWITCH

WH

BK

SWITCH LOCATED IN BLOWER
COMPARTMENT ON SOME MODELS

RD

RD

BL

PU

YL

OR

BR

(SINGLE CONTROL ON SOME MODELS)

(SINGLE CONTROL ON SOME MODELS)

DI

A

G

NO
S

T

IC

LE
D

LO
H

E

A

T

-H

PARK

SEE NOTE 6

CO
O

L

-H

HI

HE
A

T

-H

9

7

8

6

5

4

12

C

G

R

W

Y

5 MIN

2 STG

100 SEC

1 STG

AUTO

150 SEC

MODE

2N

DS

TG

DLY

HTO

FFD

LY

2

1

EAC-H

LINE-H

XFMR-H

L

INE
NE
UT
R

A

L

FS

11

10

3

2

1

CONTROL MODULE

INTEGRATED

FUSE

PM

1

HI

C

2

3

2 STAGE

GAS VALVE
(HONEY WELL)

WH

24 VAC

HUMIDIFIER

RD

HI

MVH (12)

HI

LO

HE

AT-H

AIR CLEANER

ELECTRONIC

EAC-N

EAC-H

6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH

FOR MORE THAN 2 SECONDS WHILE IN STANDBY(NO THERMOSTAT INPUTS).

WH

BL

BR

WH

BL

BK

BK

YL

YL

RD

YL

YL

PU

OR

WH

WH

WH

WH

YL

BL

RD

C

8 FLASHES = CHECK IGNITER OR IMPROPER GROUND

H

IG

H

V

O

LTA

G

E

!

D

IS

CO

NNE

CT

AL

L

PO

WER

BE

F

O

RE

SE

R

V

IC

IN

G

OR

IN

S

T

A

LLI

N

G

TH

IS

UNI

T

.

M

U

LTI

P

L

E

PO

WER

S

O

U

RCE

S

MA

Y

BE

PR

E

S

EN

T

. F

AIL

U

RE

TO

DO

SO

MA

Y

CAU

S

E

PR

O

P

E

R

T

Y

DAM

AG

E

,

P

E

RS

O

NAL

INJ

URY

OR

DE

AT

H

.