S

TART

-

UP

P

ROCEDURE

AND

A

DJUSTMENT

4. Attach a hose and manometer to the outlet pressure

barb fitting (Honeywell valve) or inlet pressure boss (White-
Rodgers valve).

5. Turn ON the gas supply.
6. Turn On power and close thermostat “R” and “W” contacts

to provide a call for heat.

7. Using a leak detection solution or soap suds, check for

leaks at outlet pressure boss plug (Honeywell valve) or
screw (White-Rodgers valve). Bubbles forming indicate
a leak. SHUT OFF GAS AND REPAIR ALL LEAKS
IMMEDIATELY!

8. Measure the gas supply pressure with burners firing.

Adjust supply pressure using the Inlet Gas Supply
Pressure
table shown below. If supply pressure reading
differs from the table, make necessary adjustments to
pressure regulator, gas piping size, etc., and/or consult
with local gas utility.

Propane Gas

Natural Gas

Inlet Gas Supply Pressure

Minimum:5.0" W.C. Maximum :10.0" W.C.
Minimum:11.0" W.C. Maximum :13.0" W.C.

9. Turn OFF all electrical power and gas supply to the

system.

10. Remove the manometer hose from the hose barb fitting

or inlet pressure boss.

11. Replace inlet pressure tap:

a. Honeywell VR8215 valve:

Remove the 1/8” NPT hose barb fitting from the inlet
pressure tap. Replace the inlet pressure boss plug
and seal with a high quality thread sealer.

b. White-Rodgers 36G22 valve:

Turn inlet pressure test screw in to seal pressure port
(clockwise, 7 in-lb minimum).

12. Retest for leaks. If bubbles form, shut down gas and

repair leaks immediately.

13. Turn ON electrical power and gas supply to the system.
14. Turn valve switch ON.

M

ODELS

USING

T

WO

S

TAGE

G

AS

V

ALVES

T

O

 

PREVENT

 

UNRELIABLE

 

OPERATION

 

OR

 

EQUIPMENT

 

DAMAGE

THE

 

GAS

 

MANIFOLD

 

PRESSURE

 

MUST

 

BE

 

AS

 

SPECIFIED

 

ON

 

THE

 

UNIT

 

RATING

 

PLATE

. O

NLY

 

MINOR

 

ADJUSTMENTS

 

SHOULD

 

BE

 

MADE

 

BY

 

ADJUSTING

 

THE

 

GAS

 

VALVE

 

PRESSURE

 

REGULATOR

.

CAUTION

The line pressure supplied to the gas valve must be within the
range specified below. The supply pressure can be measured
at the gas valve inlet pressure boss or at a hose fitting installed
in the gas piping drip leg. The supply pressure must be mea-
sured with the burners operating. To measure the gas supply
pressure, use the following procedure.

HIGH VOLTAGE !

D

ISCONNECT

 

ALL

 

POWER

 

BEFORE

 

SERVICING

 

OR

 

INSTALLING

 

THIS

 

UNIT

. M

ULTIPLE

 

POWER

 

SOURCES

 

MAY

 

BE

 

PRESENT

. F

AILURE

 

TO

 

DO

 

SO

 

MAY

 

CAUSE

 

PROPERTY

 

DAMAGE

PERSONAL

 

INJURY

 

OR

 

DEATH

.

WARNING

M

ODELS

USING

S

INGLE

S

TAGE

G

AS

V

ALVES

The line pressure supplied to the gas valve must be within the
range specified below. The supply pressure can be measured
at the gas valve inlet pressure tap or at a hose fitting installed in
the gas piping drip leg. The supply pressure must be mea-
sured with the unit OFF. To measure inlet pressure, use the
following procedure.

Pressure Regulator

Adjustment

(Under Cap Screw)

Gas Valve

On/Off

Selector

Switch

INLET

OUTLET

Inlet Pressure

Tap

Outlet Pressure

Tap

White-Rodgers Model 36G22

Gas Valve On/Off

Selector Switch

Inlet

Pressure

Tap

Pressure Regulator

(under cap screw)

Outlet

Pressure

Tap

Honeywell Model VR8215 (Single-Stage)

1. Turn OFF gas to furnace at the manual gas shutoff valve

external to the furnace.

2. Turn OFF all electrical power to the system.
3. Inlet pressure tap connections:

a. Honeywell VR8215 Valve:

Remove the inlet pressure boss plug. Install an 1/8”
NPT hose barb fitting into the outlet pressure tap.

b. White-Rodgers 36G22 valve:

Back inlet pressure test screw (inlet pressure boss)
out one turn (counterclockwise, not more than one
turn).