Installing slides in the rack – HP Netserver L Server series User Manual

Page 72

Advertising
background image

Chapter 7

Rack Mounting the HP Netserver (4-Post)

66

Installing Slides in the Rack

1. Ensure the rack is stabilized.

For HP system /E or /U racks, pull the anti-tip foot forward out of the bottom
of the rack and lower the leveler screws to make firm contact with the floor.
See Figure 7-3.

Anti-tip Foot
Extended

Leveler
Screws (4)

Figure 7-3. Installing Slides in the Rack

2. Insert the rear slide mounting pins into holes you have marked on the rear

column. Then push in on the front of the slide and snap the front mounting
pins into holes marked on the front column.

The slide mounting pins insert into the inside face of the rear column and the
front face of the front column. See Figure 7-3.