HP StorageWorks Enterprise File Services WAN Accelerator User Manual

Page 218

Advertising
background image

218

B - HP EFS WAN A

CCELERATOR

MIB

"A fan error has been detected on the appliance. Not

supported on all models"

::= { alarmsPrefix 21 }

memoryError NOTIFICATION-TYPE

STATUS current

DESCRIPTION

"A memory error has been detected on the appliance. Not

supported on all models"

::= { alarmsPrefix 22 }

--

--

-- STATISTICS

--

--

cpuLoad OBJECT IDENTIFIER

::= { statistics 1 }

cpuLoad1 OBJECT-TYPE

SYNTAX Unsigned32

MAX-ACCESS read-only

STATUS current

DESCRIPTION

"One-minute CPU load in hundreths"

::= { cpuLoad 1 }

cpuLoad5 OBJECT-TYPE

SYNTAX Unsigned32

MAX-ACCESS read-only

STATUS current

DESCRIPTION

"Five-minute CPU load in hundreths"

::= { cpuLoad 2 }

cpuLoad15 OBJECT-TYPE

SYNTAX Unsigned32

MAX-ACCESS read-only

STATUS current

DESCRIPTION

"Fifteen-minute CPU load in hundreths"

::= { cpuLoad 3 }

cpuUtil1 OBJECT-TYPE

SYNTAX Unsigned32

MAX-ACCESS read-only

STATUS current

DESCRIPTION

"Percentage CPU utilization, aggregated across all CPUs, rolling

average over the past minute"

::= { cpuLoad 4 }

cpuIndivUtilTable OBJECT-TYPE

SYNTAX SEQUENCE OF CPUIndivUtilEntry

MAX-ACCESS not-accessible

STATUS current

DESCRIPTION

"Details about the individual CPU utilization"

::= { cpuLoad 5 }

cpuIndivUtilEntry OBJECT-TYPE

SYNTAX CPUIndivUtilEntry

MAX-ACCESS not-accessible