To enable connection
pooling

1. Click the Setup tab to expand the Optimization Service menu.

2. Click Connection Pooling to display the Optimization Service - Connection

Pooling page.

Figure 2-10. Optimization Service - Connection Pooling Page

3. Under Connection Pooling Size, type the connection pooling size in the

Maximum Connection Pooling Size text box. The default value is 20.

TIP: To help you determine whether to modify the default, display the Connection Pooling
report, described in

“Viewing Connection Pooling” on page 174

. If the report indicates an

unacceptably low ratio of pool hits per total connection requests, increase the pool size.

4. Click Apply to apply your settings to the running configuration. (Apply your

settings to test a new configuration before saving them permanently.)

5. Click Save to save your settings permanently or click Reset to return the settings

to their previous values.

IMPORTANT: You must restart the HP EFS WAN Accelerator service on the HP EFS WAN

Accelerator if you have modified your connection pooling parameters. For detailed information